Customization: | Available |
---|---|
Type: | Optical Transport Network |
Certification: | CE, ISO, RoHS, GS |
Still deciding? Get samples of US$ 20000/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Specifications
|
E9624
|
E9612
|
E9605
|
|
Subrack dimensions (mm)
|
747.2 (H) x 442 (W) x 295 (D)
|
347.2 (H) x 442 (W) x 295 (D)
|
177 (H) x 442 (W) x 295 (D)
|
|
Suitable cabineta
|
ETSI 300/600 cabinets, such as A63B
|
|||
19-inch cabinet
|
||||
Max. number of service board slots
|
1:1 cross-connect mode: 12 large slots or 24 small slots
|
13
|
5
|
|
1:3 cross-connect mode: 10 large slots or 20 small slots
|
||||
NOTE:
|
||||
The E9624 subrack supports slot splitting. One 11 U slot of the E9624 subrack can be split into two 5.5 U slots.
|
||||
Switching capability
|
Optical
|
1 to 20-degree reconfigurable optical add/drop multiplexer (ROADM)
|
||
Electrical
|
1:1 cross-connect mode:
|
N/A
|
||
4.8 Tbit/s OSUflex/ODUk
|
||||
4.8 Tbit/s packet services
|
||||
1.92 Tbit/s VC-4
|
||||
160 Gbit/s VC-3/VC-12
|
||||
1:3 cross-connect mode:
|
||||
10 Tbit/s OSUflex/ODUk
|
||||
4 Tbit/s packet services
|
||||
1.6 Tbit/s VC-4
|
||||
160 Gbit/s VC-3/VC-12
|
||||
Max. number of wavelengths
|
Fixed grid:
|
|||
C band: 120 wavelengths@50GHZ
|
||||
L band: 120 wavelengths@50GHZ
|
||||
Flexible grid: The maximum number of wavelengths is related to the width of the flex channel.
|
||||
Wavelength range
|
DWDM system: 1524.50 nm to 1572.06 nm (C120 band)
|
|||
DWDM system: 1575.37 nm to 1626.21 nm (L120 Band)
|
||||
CWDM system: 1471 nm to 1611 nm (S+C+L band)
|
||||
Max. rate per channel
|
800 Gbit/s (OTUC8)
|
|||
Service type
|
SDH, SONET, PDH, Ethernet, SAN, OTN, Video, OSU
|
SDH, SONET, Ethernet, SAN, OTN, Video
|
||
Packet service capacity
|
Support for E-Line/E-LAN (MEF) and VPWS/VPLS (IETF)
|
N/A
|
||
Support for MPLS-TP
|
||||
Number of MPLS tunnels: 64 x 1024
|
||||
Number of PWs: 64 x 1024
|
||||
Number of E-Line services: 32 x 1024
|
||||
Number of E-LAN services: 8 x 1024
|
||||
Line rate
|
1.25 Gbit/s, 2.5 Gbit/s, 10 Gbit/s, 25 Gbit/s, 100 Gbit/s, 200G bit/s, 300Gbit/s, 400G bit/s, 500G bit/s, 600G bit/s, 700G bit/s,
800G bit/s |
10 Gbit/s, 100 Gbit/s, 200G bit/s, 300Gbit/s, 400G bit/s
|
||
, 500G bit/s, 600G bit/s, 700G bit/s, 800G bit/s
|
||||
Supported pluggable optical modules
|
eSFP, SFP+, TSFP+, CFP, CSFP, CFP2, QSFP28, SFP28, TSFP28, QSFP+, QSFP-DD
|
eSFP, SFP+, TSFP+, CFP, CSFP, CFP2, QSFP28, SFP28, QSFP+, QSFP-DD
|
||
Topology
|
Point-to-point, chain, star, ring, ring-with-chain, tangent ring, intersecting ring, and mesh
|
|||
Redundancy and protection
|
Network level protection (OTN)
|
Optical line protection, client 1+1 protection, ODUk SNCP, OSUflex SNCP, tributary SNCP, intra-board 1+1 protection, LPT
|
Optical line protection, client 1+1 protection, intra-board 1+1 protection, LPT, intra-board ODUk SNCP, tributary SNCP
|
|
Network level protection (Packet)
|
ERPS, LAG, PW APS/FPS, Tunnel APS, MC-LAG, MC-PW APS, LPT
|
N/A
|
||
Network Level Protection (SDH)
|
SNCP, linear MSP, ring MSP, TPS
|
N/A
|
||
Network level protection (EoS)
|
LAG, DLAG, LCAS, LPT, STP/RSTP, BPS, PPS
|
N/A
|
||
Equipment level protection
|
Power supply redundancy, fan redundancy, cross-connect board redundancy, communication control and clock processing unit
redundancy |
Power supply redundancy, fan redundancy, communication control unit redundancy, clock processing unit redundancy
|
||
Encryption type
|
Client-side service encryption
|
|||
Optical power management
|
ALS, ALC, IPA, IPA of the Raman system, IPC
|
|||
Easy O&M
|
Optical Doctor (OD) system, Fiber Doctor (FD) system
|
|||
Synchronization
|
Synchronous Ethernet, IEEE 1588v2, ITU-T G.8275.1/G.8273.2, high-precision clock synchronization
|
|||
ASON
|
Electrical-layer ASON
|
Optical-layer ASON
|
||
Optical-layer ASON
|
||||
SDH ASON
|
||||
2M ASON
|
||||
TSDN
|
Fast E2E Service Provisioning
|
|||
Bandwidth Adjustment
|
||||
Scheduled Service Provisioning
|
||||
Resource Usage View
|
||||
Latency Map
|
||||
Submarine cable features
|
Supports application of extended C band in submarine cable scenarios.
|
N/A
|
N/A
|
|
Power supply
|
DC power input
|
DC power input
|
||
Standard working voltage: -48 V DC / -60 V DC
|
Standard working voltage: -48 V / -60 V
|
|||
Working voltage range: -40 V to -72 V
|
Working voltage range: -40 V to -72 V
|
|||
AC power input
|
AC power input
|
|||
Standard working voltage: 110V AC/220V AC
|
Standard working voltage: 110V AC/220V AC
|
|||
Working voltage range:
|
Working voltage range:
|
|||
110V AC: 90V ACto 175V AC
|
110V AC: 90V AC to 176V AC
|
|||
220V AC: 175V AC to 264V AC
|
220V AC: 176V AC to 264V AC
|
|||
High-voltage DC power input
|
High-voltage DC power input
|
|||
Standard working voltage: 240V/336V HVDC
|
Standard working voltage: 240 V HVDC
|
|||
Working voltage range: 190V HVDC to 400V HVDC
|
Working voltage range: 190 V HVDC to 290 V HVDC
|
|||
NOTE:
|
NOTE:
|
|||
In IEEE1613-compliant scenarios: (There is no such requirement when other standards are used.):
|
In IEEE1613-compliant scenarios: (There is no such requirement when other standards are used.):
|
|||
The power supply to the equipment must be less than 50V
|
The power supply to the equipment must be less than 50 V.
|
|||
The communication equipment must use an independent backup power supply system. It cannot share the backup power supply system
with the power equipment. |
The communication equipment must use an independent backup power supply system. It cannot share the backup power supply system
with the power equipment. |
|||
Operation environment
|
Subrack temperature:
|
Subrack temperature:
|
Subrack temperature:
|
|
Long-term operation: 0°C to 45°C
|
Long-term operation: 0°C to 45°C
|
Long-term operation: 0°C to 50°C
|
||
Short-term operationb: -5°C to +50°C
|
Short-term operationb: -5°C to +55°C
|
Short-term operationb: -5°C to +55°C
|
||
Relative humidity:
|
Relative humidity:
|
Relative humidity:
|
||
Long-term operation: 5% to 85%
|
Long-term operation: 5% to 85%
|
Long-term operation: 5% to 85%
|
||
Short-term operationb: 5% to 90%
|
Short-term operationb: 5% to 90%
|
Short-term operationb: 5% to 90%
|
||
Mean Time To Repair (MTTR)
|
1 hoursc
|
|||
NOTE:
|
||||
Average time for only fault locating, board replacement, device restart, and service recovery, excluding component preparation and transportation time.
|
||||
Mean Time Between Failure(MTBF)
|
65.94 yearsc
|
|||
Availability
|
0.999993076c
|
|||
a: The ETSI/19-inch standard defines only part of the cabinet dimensions. Therefore, the distance between the cabinet column and door plate varies depending on cabinet manufacturers. For details about the dimensions of different subracks, see the detailed description of each subrack.
|
||||
b: Short-term operation means that the continuous operating time does not exceed 96 hours and the accumulated time per year does not exceed 15 days.
|
||||
c: The preceding parameters are calculated based on the typical product configuration. In actual use, these parameters vary according to the configured module.
|
The product is 100% genuine and has sufficient stock in stock;
Price discounts and fast delivery;
After sales service guarantee; Support sample and customization services.
Q: Are you a trading company or a manufacturer? Can I use our own logo and label?
A: We are a trading company that provides domestic and international trade services. We also provide OEM/OEM services.
Q: What are the guarantees for product quality?
A: We have professional engineers who test each piece of equipment before shipment to ensure that the shipped products are in good condition.
Q: How did you resolve a defective product when I received it?
A: We have professional personnel to help you solve the problem. If the product is defective, we usually offer you a return, refund, or replacement of the defective product.
Q: What is your payment method and delivery time?
A: We accept credit cards, wire transfers, PayPal, and other payment methods. We also support fast shipping within 72 hours.
Q: What is the MOQ and how long is the warranty period?
A: The minimum order quantity for normal products is 1, and the product warranty period is usually 1 year.