Item | CloudEngine S5331- S24T4X | CloudEngine S5331- S24T4X-A | CloudEngine S5331- S24T4X-D | CloudEngine S5331- S24P4X |
Fixed port | 24 x 10/100/1000Base-T ports, 4 x 10GE SFP+ ports | 24 x 10/100/1000Base- T ports, 4 x 10GE SFP+ ports | 24 x 10/100/1000Base-T ports, 4 x 10GE SFP+ ports | 24 x 10/100/1000Base-T (PoE+) ports, 4 x 10GE SFP+ ports |
Dimensions (H x W x D) | 43.6 mm x 442 mm x 420 mm | 43.6 mm x 442 mm x220 mm | 43.6 mm x 442 mm x 220 mm | 43.6 mm x 442 mm x 420 mm |
Chassis height | 1 U | 1 U | 1 U | 1 U |
Chassis weight (including packaging) | 4.84/8.4 kg | 3.04/4.4 kg | 3.26/4.62 kg | 8.6 kg |
Power supply type | l 150 W AC (pluggable) l 600 W AC (pluggable) l 180 W DC (pluggable) l 1000 W DC (pluggable) |
Built-in AC | Built-in DC |
l 1000 W PoE AC(pluggable)
l 1000 W PoE DC(pluggable)
|
Rated voltage range | l AC input (150 W AC ): 100 V AC to 240 V AC, 50/60 Hz l AC input (600 W AC ): 100 V AC to 240 V AC, 50/60 Hz l DC input (180/1000 W DC): -48 VDC to -60 V DC |
AC input : 100 V AC to 240 V AC, 50/60 Hz | DC input : -48 VDC to -60 V DC | l AC input (1000 W AC PoE): 100 V AC to 240 V AC, 50/60 Hz l DC input (1000 W AC PoE): 240 V DC l DC input (1000 W DC PoE): -48 VDC to -60 V DC |
Maximum voltage range | l AC input (150 W AC ): 90 V AC to 264 V AC,47 Hz to 63 Hz l AC input (600 W AC ): 90 V AC to 290 V AC,45 Hz to 65 Hz l High-voltage DC input (600 W AC): 190 V DC to 290 V DC (meeting 240 V high-voltage DC certification) l DC input (180/1000 W DC): -38.4 V DC to - 72V DC |
AC input : 90 V AC to 290 V AC, 45 Hz to 65 Hz | DC input : -38.4 V DC to - 72V DC | l AC input (1000 W AC PoE): 90 V AC to 290 V AC, 45 Hz to 65 Hz l High-voltage DC input (1000 W AC PoE): 190 V DC to 290 V DC (meeting 240 V high- voltage DC certification) l DC input (1000 W DC PoE): -38.4 V DC to - 72V DC |
Maximum power consumption | 114 W | 80 W | 76 W | l 121 W (without PD) l 977 W (with PD, PD power consumption of 720 W) |
Minimum power consumption | 44 W | 48W | 42W | 82W |
Noise | l Under normal temperature (sound power): 57.5dB (A) l Under high temperature (sound power): 70.9dB (A) l Under normal temperature (sound pressure): 47.5dB (A) |
l Under normal temperature (sound power): 44.90 dB (A) l Under high temperature (sound power): 73.80 dB (A) l Under normal temperature (sound pressure): 31.21 dB (A) |
l Under normal temperature (sound power): 44.90 dB (A) l Under high temperature (sound power): 73.80 dB (A) l Under normal temperature (sound pressure): 31.21 dB (A) |
l Under normal temperature (sound power): 62.3dB (A) l Under high temperature (sound power): 71.8dB (A) l Under normal temperature (sound pressure): 52.8dB (A) |
Operating temperature | l 0-1800 m altitude: -5° C to +45°C | l 0-1800 m altitude: - 5°C to +45°C | l 0-1800 m altitude: -5° C to +45°C | l 0-1800 m altitude: -5° C to +45°C |
l 1800-5000 m altitude: The operating temperature reduces by 1ºC every time the altitude increases by 220 m. |
l 1800-5000 m altitude: The operating temperature reduces by 1ºC every time the altitude increases by 220 m. |
l 1800-5000 m altitude: The operating temperature reduces by 1ºC every time the altitude increases by 220 m. |
l 1800-5000 m altitude: The operating temperature reduces by 1ºC every time the altitude increases by 220 m. |
|
Storage temperature | -40ºC to +70ºC | -40ºC to +70ºC | -40ºC to +70ºC | -40ºC to +70ºC |
Relative humidity | 5% to 95% (non- condensing) | 5% to 95% (non- condensing) | 5% to 95% (non- condensing) | 5% to 95% (non- condensing) |
Surge protection specification (service port) | ±6 kV | ±7 kV | ±7 kV | ±6 kV |
Surge protection specification (power port) | l AC power port: ±6 kV in differential mode, ±6 kV in common mode l DC power port: ±2 kV in differential mode, ±4 kV in common mode |
AC power port: ±6 kV in differential mode, ±6kV in common mode | DC power port: ±2 kV in differential mode, ±4kV in common mode | l AC power port: ±6 kV in differential mode, ±6 kV in common mode l DC power port: ±2 kV in differential mode, ±4 kV in common mode |
Heat dissipation | Air cooling heat dissipation, intelligent speed adjustment |
Feature | Description |
MAC address table | IEEE 802.1d standards compliance |
64K MAC address entries | |
MAC address learning and aging | |
Static, dynamic, and blackhole MAC address entries | |
Packet filtering based on source MAC addresses | |
VLAN | 4094 VLANs |
Guest VLAN and voice VLAN | |
GVRP | |
MUX VLAN | |
VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports | |
VLAN mapping | |
Ethernet loop protection | RRPP ring topology and RRPP multi-instance |
Smart Link tree topology and Smart Link multi-instance, providing millisecond-level protection switching | |
SEP | |
ERPS (G.8032) | |
BFD for OSPF, BFD for IS-IS, BFD for VRRP, and BFD for PIM | |
STP (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s) | |
BPDU protection, root protection, and loop protection | |
IP routing | Static routes, RIP v1/2, RIPng, OSPF, OSPFv3, IS-IS, IS-ISv6, BGP, BGP4+, ECMP, routing policy |
Up to 16K FIBv4 entries | |
Up to 8K FIBv6 entries | |
Interoperability | VLAN-Based Spanning Tree (VBST), working with PVST, PVST+, and RPVST |
Link-type Negotiation Protocol (LNP), similar to DTP | |
VLAN Central Management Protocol (VCMP), similar to VTP | |
IPv6 features | Up to 8K ND entries |
PMTU | |
IPv6 Ping, IPv6 Tracert, and IPv6 Telnet | |
ACLs based on source IPv6 addresses, destination IPv6 addresses, Layer 4 ports, or protocol types | |
Multicast Listener Discovery snooping (MLDv1/v2) | |
IPv6 addresses configured for sub-interfaces, VRRP6, DHCPv6, and L3VPN | |
Multicast | IGMP v1/v2/v3 snooping and IGMP fast leave |
Multicast forwarding in a VLAN and multicast replication between VLANs | |
Multicast load balancing among member ports of a trunk | |
Controllable multicast | |
Port-based multicast traffic statistics | |
IGMP v1/v2/v3, PIM-SM, PIM-DM, and PIM-SSM | |
MSDP | |
MVPN | |
QoS/ACL | Rate limiting in the inbound and outbound directions of a port |
Packet redirection | |
Port-based traffic policing and two-rate three-color CAR | |
Eight queues per port | |
DRR, SP and DRR+SP queue scheduling algorithms | |
WRED | |
Re-marking of the 802.1p and DSCP fields of packets | |
Packet filtering at Layer 2 to Layer 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, TCP/UDP port number, protocol type, and VLAN ID | |
Queue-based rate limiting and shaping on ports | |
Security | Hierarchical user management and password protection |
DoS attack defense, ARP attack defense, and ICMP attack defense | |
Binding of the IP address, MAC address, port number, and VLAN ID | |
Port isolation, port security, and sticky MAC | |
MAC Forced Forwarding (MFF) | |
Blackhole MAC address entries | |
Limit on the number of learned MAC addresses | |
IEEE 802.1x authentication and limit on the number of users on a port | |
AAA authentication, RADIUS authentication, and HWTACACS authentication | |
NAC | |
SSH V2.0 | |
HTTPS | |
CPU protection | |
Blacklist and whitelist | |
Attack source tracing and punishment for IPv6 packets such as ND, DHCPv6, and MLD packets | |
Secure Boot | |
IPSec | |
Reliability | LACP |
E-trunk | |
Ethernet OAM (IEEE 802.3ah and IEEE 802.1ag) | |
ITU-Y.1731 | |
DLDP | |
LLDP | |
BFD for BGP, BFD for IS-IS, BFD for OSPF, BFD for static route | |
VXLAN* | VXLAN L2 and L3 gateways |
Centralized and distributed gateway | |
BGP-EVPN | |
Configured through the NETCONF protocol | |
Super Virtual Fabric (SVF) | A two-layer client architecture is supported. |
IGMP snooping can be enabled on access switches (ASs) and the maximum number of access users on a port can be configured. | |
ASs can be independently configured. Services that are not supported by templates can be configured on the parent. | |
Third-party devices are allowed between SVF parent and clients. | |
Working as an SVF client that is plug-and-play with zero configuration | |
iPCA | Directly coloring service packets to collect real-time statistics on the number of lost packets and packet loss ratio |
Collection of statistics on the number of lost packets and packet loss ratio at network and device levels | |
TWAMP | Two-way IP link performance measurement |
Measurement on two-way packet delay, one-way packet loss rate, and one-way packet jitter | |
Management and maintenance | iStack, with up to 9 member switches in a stack |
SNMP v1/v2c/v3 | |
RMON | |
Smart Application Control (SAC) | |
Web-based NMS | |
System logs and alarms of different levels | |
GVRP | |
MUX VLAN | |
NetStream | |
Intelligent O&M |
Model | Product Description |
CloudEngine S5331-S32ST4X | CloudEngine S5331-S32ST4X(8*10/100/1000BASE-T ports, 24*GE SFP ports, 4*10GE SFP+ ports, without power module) |
CloudEngine S5331-S32ST4X-A | CloudEngine S5331-S32ST4X-A(8*10/100/1000BASE-T ports, 24*GE SFP ports, 4*10GE SFP+ ports, AC power, front access) |
CloudEngine S5331-S32ST4X-D | CloudEngine S5331-S32ST4X-D(8*10/100/1000BASE-T ports, 24*GE SFP ports, 4*10GE SFP+ ports, DC power, front access) |
CloudEngine S5331-S24S8T4X-A | CloudEngine S5331-S24S8T4X-A(24*GE SFP ports, 8*10/100/1000BASE-T ports, 4*10GE SFP+ ports, AC power, front access) |
CloudEngine S5331-S24S8T4X-D | CloudEngine S5331-S24S8T4X-D(24*GE SFP ports, 8*10/100/1000BASE-T ports, 4*10GE SFP+ ports, DC power, front access) |
CloudEngine S5331-S48S4X | CloudEngine S5331-S48S4X(48*GE SFP ports, 4*10GE SFP+ ports, without power module) |
CloudEngine S5331-S48S4X-A | CloudEngine S5331-S48S4X-A(48*GE SFP ports, 4*10GE SFP+ ports, AC power, front access) |
CloudEngine S5331-S48S4X-D | CloudEngine S5331-S48S4X-D(48*GE SFP ports, 4*10GE SFP+ ports, DC power, front access) |
CloudEngine S5331-S24T4X | CloudEngine S5331-S24T4X (24*10/100/1000BASE-T ports, 4*10GE SFP+ ports, without power module) |
CloudEngine S5331-S24T4X-A | CloudEngine S5331-S24T4X-A (24*10/100/1000BASE-T ports, 4*10GE SFP+ ports, AC power) |
CloudEngine S5331-S24T4X-D | CloudEngine S5331-S24T4X-D (24*10/100/1000BASE-T ports, 4*10GE SFP+ ports, DC power) |
CloudEngine S5331-S24P4X | CloudEngine S5331-S24P4X (24*10/100/1000BASE-T (PoE+) ports, 4*10GE SFP+ ports, without power module) |
CloudEngine S5331-S48T4X | CloudEngine S5331-S48T4X (48*10/100/1000BASE-T ports, 4*10GE SFP+ ports, without power module) |
CloudEngine S5331-S48T4X-A | CloudEngine S5331-S48T4X-A (48*10/100/1000BASE-T ports, 4*10GE SFP+ ports, AC power) |
CloudEngine S5331-S48P4X | CloudEngine S5331-S48P4X (48*10/100/1000BASE-T (PoE+) ports, 4*10GE SFP+ ports, without power module) |
PAC150S12-R | 150 W AC power module |
PDC180S12-CR | 180 W DC power module |
PAC1000S56-CB | 1000 W AC PoE power module |
PDC1000S56-CB | 1000 W DC PoE power module |
S53S-M-Lic | S53XX-S Series Basic SW,Per Device |
The product is 100% genuine and has sufficient stock in stock;
Price discounts and fast delivery;
After sales service guarantee; Support sample and customization services.
Q: Are you a trading company or a manufacturer? Can I use our own logo and label?
A: We are a trading company that provides domestic and international trade services. We also provide OEM/OEM services.
Q: What are the guarantees for product quality?
A: We have professional engineers who test each piece of equipment before shipment to ensure that the shipped products are in good condition.
Q: How did you resolve a defective product when I received it?
A: We have professional personnel to help you solve the problem. If the product is defective, we usually offer you a return, refund, or replacement of the defective product.
Q: What is your payment method and delivery time?
A: We accept credit cards, wire transfers, PayPal, and other payment methods. We also support fast shipping within 72 hours.
Q: What is the MOQ and how long is the warranty period?
A: The minimum order quantity for normal products is 1, and the product warranty period is usually 1 year.