Customization: | Available |
---|---|
Type: | Network Cabinet |
Usage: | Network Integration System, Remote Monitoring System, Closed-Circuit Monitoring System, Electronic Monitoring System, Wireless Monitoring System |
Still deciding? Get samples of US$ 2000/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item | TP48200B-N20 B2 | TP48200B-L20 B2 | TP48200B-N20 B3 | TP48400B-N20 B3 | TP48400B-L20 B1 |
AC input system | 220/380 V AC three-phase, four-wire input system (compatible with 220 V AC single-phase input systems) |
110 V dual-live wire input system (compatible with 220 V AC single-phase input systems) | 220/380 V AC three-phase, four-wire input system (compatible with 220 V AC single-phase input systems) |
220/380 V AC three-phase, four-wire |
220 V AC three-phase, three-wire |
AC power distribution | AC input: one 3-pole 63 A circuit breaker | AC input: one 2-pole 100 A circuit breaker | AC input: one 3-pole 63 A circuit breaker | AC input: one 3-pole 63 A circuit breaker | AC input: one 3-pole 100 A circuit breaker |
Rectifier | l Four available slots l A maximum of four R4850G2s |
l Eight available slots l A maximum of eight R4850G2s |
|||
SSU (optional) |
A maximum of two S4850G1s | N/A | |||
PV distribution unit (PVDU) (optional) |
Mandatory when SSUs are configured | N/A | |||
SMU and UIM | SMU02B and UIM02C | ||||
DC power distribution | BLVD route l Standard circuit breakers: two 1-pole 32 A circuit breakers, three 1-pole 16 A circuit breakers, and one 1-pole 10 A circuit breaker |
BLVD route l Standard circuit breakers: four 1-pole 63 A circuit breakers, two 1-pole 16 A circuit breakers, and |
|||
l Extended circuit breakers: ten 1-pole 1-63 A circuit breakers |
two 1-pole 10 A circuit breakers l Extended circuit breaker: eight 1-pole 1-63 A circuit breakers |
||||
LLVD route l Standard circuit breakers: two 1-pole 80 A circuit breakers, one 1-pole 32 A circuit breaker, and two 1-pole 20 A circuit breakers l Extended circuit breakers: two 1-pole 1-125 A circuit breakers and thirteen 1-pole 1-63 A circuit breakers |
LLVD route l Standard circuit breakers: two 1-pole 100 A circuit breakers, two 1-pole 63 A circuit breakers, four 1-pole 32 A circuit breakers, and two 1-pole 16 A circuit breakers l Extended circuit breakers: two 1-pole 1-125 A circuit breakers and eight 1-pole 1-63 A circuit breakers |
||||
Battery route: two 1-pole 125 A circuit breakers | Battery route: two 1-pole 125 A circuit breakers | Battery route: four 1-pole 125 A circuit breakers | Battery route: four 1-pole 125 A circuit breakers | Battery route: four 1-pole 125 A circuit breakers | |
DC-DC power system (optional) |
A maximum of four PW48S24Cs are supported. | A maximum of four PW48S24Cs are supported. |
N/A | N/A | N/A |
Baseband unit (BBU) components (optional) | BBUs should be installed from the top down. Optional BBU components include BBU installation components (8 U), a BBU air baffle (1 U), BBU fan installation components (16 U), and a side compartment (H x W x D: 2000 mm x 100 mm x 600 mm). l When one or two BBUs are configured, no BBU components are required. Install the BBUs on the customer components. l When three to five BBUs are configured, BBU installation components, BBU air baffles, BBU fan installation components, and side compartments are required. l When six to eight BBUs are configured, BBU installation components, BBU fan installation components, and a side compartment are required. |
N/A | N/A | N/A | |
Battery | A maximum of two 150 Ah battery strings | A maximum of two 150 Ah battery strings | A maximum of four 150 Ah battery strings | A maximum of four 150 Ah battery strings | A maximum of four 150 Ah battery strings |
Space for customer equipment | 16 U | 16 U | N/A | N/A | N/A |
Sensors | l Mandatory: one battery temperature sensor l Optional: one temperature and humidity sensor |
||||
SPD | l AC surge protection. Nominal lightning strike discharge current: 20 kA (8/20 µs); maximum lightning strike discharge current: 40 kA (8/20 µs) l DC surge protection. Differential mode: 10 kA (8/20 µs); common mode: 20 kA (8/20 µs) |
||||
Maximum output power | 12 kW | 12 kW | 12 kW | 24 kW | 24 kW |
The product is 100% genuine and has sufficient stock in stock;
Price discounts and fast delivery;
After sales service guarantee; Support sample and customization services.
Q: Are you a trading company or a manufacturer? Can I use our own logo and label?
A: We are a trading company that provides domestic and international trade services. We also provide OEM/OEM services.
Q: What are the guarantees for product quality?
A: We have professional engineers who test each piece of equipment before shipment to ensure that the shipped products are in good condition.
Q: How did you resolve a defective product when I received it?
A: We have professional personnel to help you solve the problem. If the product is defective, we usually offer you a return, refund, or replacement of the defective product.
Q: What is your payment method and delivery time?
A: We accept credit cards, wire transfers, PayPal, and other payment methods. We also support fast shipping within 72 hours.
Q: What is the MOQ and how long is the warranty period?
A: The minimum order quantity for normal products is 1, and the product warranty period is usually 1 year.