Customization: | Available |
---|---|
Communication Mode: | Full-Duplex & Half-Duplex |
Type: | Ethernet Switch |
Still deciding? Get samples of US$ 50000/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item | CloudEngine 8850E -32CQ-EI | CloudEngine 8850-64CQ-EI |
Port description | 32 x 100GE QSFP28 + 1 x 10GE SFP+ | 64 x 100GE QSFP28 |
Switching capacity | 6.4 Tbps/102.4 Tbps | 12.8 Tbps/204.8 Tbps |
Packet forwarding rate | 2003 Mpps | 4482 Mpps |
Buffer | 32 MB | 42 MB |
Air duct type | Standard front-to-back or back-to-front airflow | |
Device virtualization | Intelligent stack (iStack) | |
M-LAG | ||
Data center interconnect (DCI) | VXLAN mapping, enabling Layer 2 interconnection between DCs | |
Network virtualization | VXLAN routing and VXLAN bridging | |
BGP-EVPN | ||
TRILL (supported only by the CloudEngine 8850-64CQ-EI) | ||
QinQ access VXLAN | ||
SDN | iMaster NCE-Fabric | |
Network convergence | Fibre Channel over Ethernet (FCoE) | |
Data Center Bridging Exchange Protocol (DCBX), Priority-based Flow Control (PFC), and expanded trunking system (ETS) | ||
Remote direct memory access (RDMA) and RoCE (RoCEv1 and RoCEv2) | ||
Programmability | OPS programming | |
Ansible-based automatic configuration and open-source module release | ||
Traffic analysis | NetStream | |
sFlow | ||
VLAN | Access, trunk, and hybrid ports | |
Default VLAN | ||
QinQ | ||
MUX VLAN | ||
GARP VLAN Registration Protocol (GVRP) | ||
MAC address entry | Automatic MAC address learning and aging | |
Static, dynamic, and blackhole MAC address entries | ||
Source MAC address filtering | ||
MAC address learning limiting by port and VLAN ID | ||
IP routing | IPv4 dynamic routing protocols such as RIP, OSPF, IS-IS, and BGP | |
IPv6 dynamic routing protocols such as RIPng, OSPFv3, IS-ISv6, and BGP4+ | ||
IPv6 | IPv6 VXLAN over IPv4 | |
VXLAN over IPv6 (supported only by the CE8850E-32CQ-EI) | ||
IPv6 neighbor discovery (ND) | ||
Path MTU Discovery (PMTU) | ||
TCP6, IPv6 ping, IPv6 tracert, IPv6 socket, UDP6, and raw IPv6 | ||
Multicast | Multicast routing protocols, such as the Internet Group Multicast Protocol (IGMP), Protocol Independent Multicast-Sparse Mode (PIM-SM), Protocol Independent Multicast-Dense Mode (PIM-DM), Multicast Source Discovery Protocol (MSDP), and Multicast BGP (MBGP) | |
IGMP snooping | ||
IGMP proxy | ||
Fast leaving of multicast member interfaces | ||
Multicast traffic suppression | ||
Multicast VLAN | ||
Multicast VXLAN | ||
MPLS | Basic MPLS | |
Reliability | Link Aggregation Control Protocol (LACP) | |
STP, RSTP, VBST, and MSTP | ||
BPDU protection, root protection, and loop prevention | ||
Smart Link and multi-instance | ||
Device Link Detection Protocol (DLDP) | ||
Hardware-based Bidirectional Forwarding Detection (BFD), with a minimum packet sending interval of 3.3 ms | ||
G.8032 Ethernet Ring Protection Switching (ERPS) | ||
VRRP, VRRP load sharing, and BFD for VRRP | ||
BFD for BGP, IS-IS, OSPF, and static routing | ||
BFD for VXLAN | ||
QoS | Traffic classification based on Layer 2 protocol headers, Layer 3 protocol headers, and Layer 4 protocol priorities | |
ACL, CAR, re-marking, and scheduling | ||
Queue scheduling modes such as PQ, WRR, DRR, PQ+WRR, and PQ+DRR | ||
Congestion avoidance mechanisms such as WRED and tail drop | ||
Traffic shaping | ||
Intelligent O&M | Network-wide path detection | |
1588v2 (supported only by the CloudEngine 8850-64CQ-EI) | ||
Telemetry | ||
INT (IOAM) and enhanced ERSPAN | ||
Intelligent traffic analysis | ||
RoCE traffic visualization: RoCE traffic KPI analysis | ||
Statistics collection on the buffer microburst status | ||
VXLAN OAM: VXLAN ping and VXLAN tracert | ||
Intelligent lossless network | PFC deadlock prevention | |
AI ECN: The switch intelligently adjusts the ECN thresholds of lossless queues based on the live-network traffic model. | ||
Fast CNP: The switch directly sends CNP packets to server NICs at the source end to shorten the CNP feedback path. | ||
DLB | ||
ECN overlay | ||
INC (supported only by the CE8850-64CQ-EI) | ||
Configuration and maintenance | Terminal login through the console port, Telnet, and SSH | |
Network management protocols, such as SNMPv1/v2/v3 | ||
File upload and download through FTP and TFTP | ||
Boot Read-Only Memory (BootROM) upgrade and remote online upgrade | ||
802.3az Energy Efficient Ethernet (EEE) | ||
Hot patch | ||
User operation log | ||
Configuration rollback | ||
ZTP | ||
Security and management | 802.1X authentication | |
Command line authority control based on user levels, preventing unauthorized users from using commands | ||
Defense against DoS, ARP, and ICMP attacks | ||
Port isolation, port security, and sticky MAC | ||
Binding of the IP address, MAC address, port ID, and VLAN ID | ||
Authentication methods, including AAA, RADIUS, and HWTACACS | ||
RMON | ||
Dimensions (H x W x D) | 442.0mm × 420.0mm × 43.6mm | 442.0mm×600.0mm×86.1mm |
Weight (full configuration) | 8.6 kg | 16.4 kg |
Environment requirements | Operating temperature: 0°C to 40°C (0 m to 1800 m) Storage temperature: -40°C to +70°C Relative humidity: 5% RH to 95% RH (noncondensing) |
|
Operating voltage | 600 W AC&240 V DC power module: AC: 90 V AC to 290 V AC, 45 Hz to 65 Hz DC: 190 V DC to 290 V DC 1000 W DC power module: -38.4 V DC to -72 V DC 1200 W high-voltage DC power module: 190 V DC to 400 V DC |
1200 W AC&240 V DC power module: AC: 90 V AC to 290 V AC, 45 Hz to 65 Hz DC: 190 V DC to 290 V DC 1200 W DC power module: -38.4 V DC to -72 V DC; +38.4 V DC to +72 V DC |
Typical power consumption | 203 W (100% traffic load, copper cables on half of the ports, normal temperature, dual AC power modules) 244 W (100% traffic load, short-distance optical modules on half of the ports, normal temperature, dual AC power modules) |
376 W (100% traffic load, QSFP28 high-speed cables on 32 ports, normal temperature, dual AC power modules) 455 W (100% traffic load, QSFP28 short-distance optical modules on 32 ports, normal temperature, dual AC power modules) |
Maximum power consumption | 339 W (100% traffic load, short-distance optical modul es on all ports, normal temperature, dual AC power m odules) 450 W (100% traffic load, long-distance optical modul es on all ports, 40°C, dual AC power modules) |
629 W (100% traffic load, QSFP28 short-distance o ptical modules on 64 ports, normal temperature, du al AC power modules) 965 W (100% traffic load, QSFP28 long-distance op tical modules on 64 ports, 40°C, dual AC power mo dules) |
Power factor | 0.85 @ 15%-25% load 0.92 @ 25%-50% load 0.98 @ 50%-100% load |
0.90 @ 15%-25% load 0.96 @ 25%-100% load 0.98 @ 100% load |
Item | CloudEngine 8850E - 32CQ-EI | CloudEngine 8850-64CQ- EI |
Maximum number of MAC address entries | 288K | 264K |
Maximum number of routes (FIB IPv4) | 380K | 360K |
IPv4 FIB entry specification (Flexible resource mode) | 1. Flexible resource mode excluding route resources: same as the specifications in large MAC table mode 2. Flexible resource mode including route resources: 190,000 |
1. Flexible resource mode excluding route resources: same as the specifications in large MAC table mode 2. Flexible resource mode including route resources: (1) If the IPv6 route resource mode is not set to maximum IPv6 mode or maximum dual- stack mode: 180,000 (2) If the IPv6 route resource mode is set to maximum IPv6 mode or maximum dual-stack mode: The IPv6 route resource mode is set to maximum IPv6 mode: 0 (not supporting IPv4 FIB) |
ARP size | Large ARP table mode: 168,000 per chassis; Standard mode (default mode): 64,000 per chassis; Flexible resource mode including ARP resources: 104,000 per chassis; |
Large ARP mode: 156,000; standard mode (default mode): 48,000 (among which 8,000 entries; Flexible resource mode including ARP resources: 92,000; |
Maximum number of VRFs | 4096 | 2048 |
IPv6 ND table size | Large ARP table mode: 64,000 per chassis; Large MAC table/Large ACL/flexible resource mode excluding ARP or route resources: 8,000 per chassis; Standard mode (default mode): 1. If the IPv6 route resource mode is not set to shared mode, the specification is 8,000 ND entries per chassis. 2. If the IPv6 route resource mode is set to shared mode, the specification is 64,000 ND entries per chassis. |
Large ARP table mode: 48,000; Standard mode (default mode): 1. If the IPv6 route resource mode is not set to maximum IPv6 mode or maximum dual- stack mode: 4,000; 2. If the IPv6 route resource mode is set to maximum IPv6 mode or maximum dual-stack mode: 48,000; Flexible resource mode: 1. Flexible resource mode excluding ARP or route resources: same as the specifications in large MAC table mode; 2. Flexible resource mode including ARP resources: same as the specifications in large ARP table mode; 3. Flexible resource mode including route resources: same as the standard mode; |
Maximum number of VRRP groups | 1000 (shared by VRRP and VRRP6) | 1000 (shared by VRRP and VRRP6) |
Maximum number of ECMP paths | 128 | 128 |
Maximum number of VXLAN bridge domains | M-LAG:4,000 Others:16,000 |
8000 |
Maximum number of BDIF interfaces | Default mode: 4,000 Large overlay mode: 8,000 |
4000 |
Maximum number of LAGs | 1024 | 1024 |
Maximum number of links in a LAG | Maximum number of LAGs x Maximum number of members in a LAG: 1024*2 512*4 256*8 128*16 64*32 |
Maximum number of LAGs x Maximum number of members in a LAG: 1024*2 512*4 256*8 128*16 64*32 32*64 |
Maximum number of VLANs where VBST can be configured | The number of instances supported by VBST is 500, the static instance configuration range is 1 to 63, and the dynamic instance is specified from 1 to 500. | The number of instances supported by VBST is 500, the static instance configuration range is 1 to 63, and the dynamic instance is specified from 1 to 500. |
Active Device | ||
CE8850-EI-F-B0B | CE8850-64CQ-EI Switch(64-Port 100GE QSFP28,2*AC Power Module,Port-side Exhaust) | |
CE8850-EI-B-B0B | CE8850-64CQ-EI Switch(64-Port 100GE QSFP28,2*AC Power Module,Port-side Intake) | |
CE8850-64CQ-EI | CE8850-64CQ-EI Switch(64-Port 100GE QSFP28,Without Fan and Power Module) | |
CE8850E-32CQ-EI | CE8850E-32CQ-EI Switch(32*100GE QSFP28,1*10GE SFP+,without fan and power module) | |
CE8850E-32CQ-EI-B | CE8850E-32CQ-EI Switch(32*100GE QSFP28,1*10GE SFP+,2*AC power module,4*fan module,port- side intake) | |
CE8850E-32CQ-EI-F | CE8850E-32CQ-EI Switch(32*100GE QSFP28, 1*10GE SFP+, 2*AC power module,4*fan module, port-side exhaust) | |
Power module | ||
Model | Description | Applicable product |
PHD-1K2WA-F | 1200W HVDC Power Module(Power panel side intake) | CE8850-64CQ-EI |
PHD-1K2WA-B | 1200W HVDC Power Module(Power panel side exhaust) | CE8850-64CQ-EI |
PDC-1K2WA-B | 1200W DC Power Module(Power panel side intake) | CE8850-64CQ-EI |
PDC-1K2WA-F | 1200W DC Power Module(Power panel side exhaust) | CE8850-64CQ-EI |
PAC1K2S12-PB | 1200W AC&240V DC Power Module (Back to Front,Power panel side exhaust) | CE8850-64CQ-EI |
PAC1K2S12-PF | 1200W AC&240V DC Power Module (Front to Back,Power panel side intake) | CE8850-64CQ-EI |
PHD1K2S12-DB | 1200W HVDC Power Module (Back to Front,Power panel side exhaust) | CE8850E-32CQ-EI |
PDC1000S12-DB | 1000W DC Power Module (Power panel side exhaust) | CE8850E-32CQ-EI |
PDC1000S12-DF | 1000W DC Power Module (Power panel side intake) | CE8850E-32CQ-EI |
PAC600S12-EB | 600W AC&240V DC Power Module (Back to Front,Power panel side exhaust) | CE8850E-32CQ-EI |
PAC600S12-EF | 600W AC&240V DC Power Module (Front to Back,Power panel side intake) | CE8850E-32CQ-EI |
Fan module | ||
Model | Description | Applicable product |
FAN-180A-F | Fan box(F,FAN panel side intake) | CE8850-64CQ-EI |
FAN-180A-B | Fan box(B,FAN panel side exhaust) | CE8850-64CQ-EI |
FAN-031A-F | Fan box(F,FAN panel side intake) | CE8850E-32CQ-EI |
FAN-031A-B | Fan box(B,FAN panel side exhaust) | CE8850E-32CQ-EI |
Software | ||
CE88-LIC-BUN01 | CE8800 Function License Bundle 1 | |
CE88-LIC-TLM | CE8800 Telemetry Function | |
CE88-LIC-PTP | CE8800 PTP Function (supported only by the CE8850-64CQ-EI) | |
CE88-LIC-AIF | CloudEngine 8800 AI Fabric Function | |
N1-CE88LIC-CFFD | N1-CloudFabric Foundation SW License for CloudEngine 8800 | |
N1-CE88CFFD-SnS1Y | N1-CE8800 CloudFabric Foundation Software Package-Subscription and Support-Year | |
N1-CE88LIC-CFAD | N1-CE8800 CloudFabric Advanced Software Package-Subscription and Support-Year | |
N1-CE88CFAD-SnS1Y | N1-CE8800 CloudFabric Advanced Software Package-Subscription and Support-Year | |
N1-CE88LIC-CFPM | N1- CloudEngine 8800 CloudFabric Premium Software Package | |
N1-CE88CFPM-SnS1Y | N1- CloudEngine 8800 CloudFabric Premium Software Package-Subscription and Support-Year | |
N1-CE88LIC-AIF | N1-CloudEngine 8800 AI Fabric Function | |
N1-CE88AIF-SnS1Y | N1-CE8800 AI Fabric Function-Subscription and Support-Year | |
N1-CE88LIC-HPC | N1-CloudEngine 8800 AI Fabric HPC Scenario Value-added Package | |
N1-CE88HPC-SnS1Y | N1-CloudEngine 8800 AI Fabric HPC Storage Scenario Value-added Package-Subscription and Support-Year | |
N1-CE-F-LIC-MDCA | N1-CloudEngine Data Center Switch Multi-cloud Multi-DC Value-added Package - Fixed | |
N1-CEFMDCA -SnS1Y | N1-CloudEngine Data Center Switch Multi-cloud Multi-DC Value-added Package, Per Fixed Device- Subscription and Support-Year | |
N1-CE88UPG-F-A | N1-CloudEngine 8800 Upgrade SW License: Foundation to Advanced | |
N1-CE88UGFA-SnS1Y | N1-CloudEngine 8800 Upgrade SW License: Foundation to Advanced- Subscription and Support-Year | |
N1-CE88UPG-A-P | N1-CloudEngine 8800 Upgrade SW License: Advanced to Premium | |
N1-CE88UGAP-SnS1Y | N1-CloudEngine 8800 Upgrade SW License: Advanced to Premium-Subscription and Support-Year |
The product is 100% genuine and has sufficient stock in stock;
Price discounts and fast delivery;
After sales service guarantee; Support sample and customization services.
Q: Are you a trading company or a manufacturer? Can I use our own logo and label?
A: We are a trading company that provides domestic and international trade services. We also provide OEM/OEM services.
Q: What are the guarantees for product quality?
A: We have professional engineers who test each piece of equipment before shipment to ensure that the shipped products are in good condition.
Q: How did you resolve a defective product when I received it?
A: We have professional personnel to help you solve the problem. If the product is defective, we usually offer you a return, refund, or replacement of the defective product.
Q: What is your payment method and delivery time?
A: We accept credit cards, wire transfers, PayPal, and other payment methods. We also support fast shipping within 72 hours.
Q: What is the MOQ and how long is the warranty period?
A: The minimum order quantity for normal products is 1, and the product warranty period is usually 1 year.