Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn

  • Audited Supplier
  • 3 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Images of Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn

Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn
Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn pictures & photos
Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn
Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn pictures & photos
Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn
Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn pictures & photos
Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn
Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn pictures & photos
Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn
Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn pictures & photos
Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn
Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn pictures & photos
Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn
  • Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn
  • Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn
    Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn
  • Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn
    Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn
  • Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn
    Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn
  • Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn
    Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn
  • Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn
    Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn
  • Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn
    Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn

Find Similar Products

Product Description

Product Description

OptiXstar C820 A TMH4UXCL212
OptiX OSN 820 is a wavelength division based all outdoor active transmission device, mainly suitable for all outdoor integrated forward transmission scenarios in wireless CRAN network construction mode. It supports mixed transmission of CPRI 2~CPRI 10, eCPRI 25G, GE/10GE LAN, OBSAI, and SDH services.
Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn
Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn

Technical Specification

Item
Specification
Dimensions (H x W x D)
44 mm x 442 mm x 220 mm (excluding mounting ears)
Weight (empty chassis)
AC: 5.1 kg
DC: 3.8 kg
Typical power consumption
AC: 116 W
DC: 97 W
Maximum power consumption
AC: 127 W
DC: 106 W
Circuit breaker specification
10 A
Power supply
AC: 100 V to 240 V
DC: -48 V to -60 V
Installation mode
19-inch cabinet
ETSI 300 mm deep cabinet, such as A63B and N63B
Wall-mounted
Open rack
Client-side capability
TX1/RX1 to TX2/RX2: 2 x 10GE/GE/FE/STM-1/4/16/64 (optical ports)
TX3/RX3 to TX6/RX6: 4 x GE (optical ports)
TX7/RX7 to TX8/RX8: 2 x GE/FE/STM-1/4/16 (optical ports)
FE/GE1 to FE/GE4: 4 x GE/FE (electrical ports)
NOTE:
Optical ports TX1/RX1 to TX8/RX8 are compatible with electrical modules.
For details about the services supported by client-side ports, see Table 2-19.
Line-side capability
2 x OTU1/2 x OTU2(e)/2 x STM-1/2 x STM-4/2 x STM-16/2 x STM-64/2 x 10GE LAN
Service model
EoO/EoS/EoSoO/OSU/SDH/MPLS-TP/Client
Maximum upstream bandwidth
2 x 10 Gbit/s
Service encapsulation level
VC-12/VC-3/VC-4/VC-4-4c/VC-4-16c/VC-4-64c/ODU0/ODU1/ODU2/ODU2e/ODUflex/OSUflex
Service cross-connection level
VC-12/VC-3/VC-4/ODU0/ODU1/ODU2/ODU2e/ODUflex/OSUflex
Service cross-connect capacity
OTN
40G
NOTE:
The service cross-connect capacity is shared by ODUk and OSUflex.
SDH
32.5G for higher-order cross-connections and 5G for lower-order cross-connections
Packet
30G
VCTRUNK specifications
Quantity: 8
Each VCTRUNK can be bound to a maximum of 8 x VC-4s, 24 x VC-3s, or 63 x VC-12s.
An NE supports a maximum of 16 x VC-4s, 48 x VC-3s, or 252 x VC-12s.
NOTE:
All VC-4s can be bound as VC-3 or VC-4 channels. Only the first to fourth VC-4s can be bound as VC-12 channels.
OTN functions
OSU
Supported
NOTE:
The OSU function requires license authorization. For details, see WDM OTN License Guide.
The board supports a maximum of 32 OSUflex channels.
OTN protection
ODUk SNCP, OSUflex SNCP, LPT
ALS
Supported
Packet functions
Packet protection
LPT, Tunnel APS, PW APS, ERPS, SNCP, LAG
QoS
Supported
MPLS-TP
Supported
LLDP
Supported
Ethernet OAM
Supported (CC/LM/DM)
MPLS-TP OAM
Supported (CC/LB/LT)
SDH function
SDH protection
Linear MSP, SNCP
EoS function
QinQ
Supported
 
NOTE:
A VLAN list can be configured for C-VLAN transparent transmission E-Line services of the EVPL type, and each VLAN ID occupies a service.
 
ETH OAM
Supported
EoS protection
LCAS
Port MTU
64 bytes to 9600 bytes. The default value is 9600 bytes.
Physical-layer clock
Supported
Power-off notice
Supported
DCN
Outband DCN
NCE Controller
Automatic rollout
E2E service provisioning
Automatic service provisioning
Bandwidth on demand (BoD)
Delay measurement
Latency map (upstream transmission through the OTU1 or OTU2 port)
Device operating temperature
Long term: -5°C to +65°C
Short term: -20°C to +65°C
NOTE:
If the device runs at a temperature ranging from -5°C to +55°C, commercial optical modules can be used. If the device runs at a temperature ranging from -20°C to +65°C, industrial optical modules must be used.
Device operating humidity
Long term: 5% to 85%
Short term: 5% to 95%
NOTE:
A short term refers to a maximum of 96 consecutive operating hours and a total operating time of no more than 15 days in a year.
MTTR (mean time to repair)
1 houra
NOTE:
The MTTR is related to the specific configuration of a device, including the average time for locating a fault on site, replacing a board, restarting the device, and recovering services. The traveling time is not included.
MTBF (mean time between failures)
AC: 55.45 yearsa
DC: 55.97 yearsa
 

Product Display

Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn

Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A OsnOptixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn

Related Products

Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A OsnOptixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A OsnOptixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn

Company Profile

Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn
Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A OsnOptixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn

Our Advantages

The product is 100% genuine and has sufficient stock in stock;
Price discounts and fast delivery;
After sales service guarantee; Support sample and customization services.

FAQ

Q: Are you a trading company or a manufacturer? Can I use our own logo and label?
A: We are a trading company that provides domestic and international trade services. We also provide OEM/OEM services.

Q: What are the guarantees for product quality?
A: We have professional engineers who test each piece of equipment before shipment to ensure that the shipped products are in good condition.

Q: How did you resolve a defective product when I received it?
A: We have professional personnel to help you solve the problem. If the product is defective, we usually offer you a return, refund, or replacement of the defective product.

Q: What is your payment method and delivery time?
A: We accept credit cards, wire transfers, PayPal, and other payment methods. We also support fast shipping within 72 hours.

Q: What is the MOQ and how long is the warranty period?
A: The minimum order quantity for normal products is 1, and the product warranty period is usually 1 year.

Optixstar C820 a Tmh4uxcl212 Electric Port Conversion Module Wavelength Division Equipment C820A Osn

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR256454". Items marked "verified" are certified.

Watch Video
Watch Video
Hengtian Hongyang (Beijing) Information Technology Co., Ltd
Hengtian Hongyang (Beijing) Information Technology Co., Ltd
Hengtian Hongyang (Beijing) Information Technology Co., Ltd
Hengtian Hongyang (Beijing) Information Technology Co., Ltd
Hengtian Hongyang (Beijing) Information Technology Co., Ltd
Hengtian Hongyang (Beijing) Information Technology Co., Ltd
Hengtian Hongyang (Beijing) Information Technology Co., Ltd
Hengtian Hongyang (Beijing) Information Technology Co., Ltd

About Our Factory & Business Background

verified Business Type
Trading Company
Address
Room 209, Unit 1, 2nd Floor, Building 1, No. 9 Anningzhuang West Santiao, Haidian District, Beijing, China
verified Plant Area
58 square meters
verified Number of Employees
10
verified Registered Capital
1,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: one month
verified Nearest Port
Tianjin Port, Guangzhou Port
verified Minimum Order Quantity
1
verified Supply Chain Partners
25

Our Production Capability & Technical Expertise

verified Main Products
Wireless Microwave, Switch, Router, Firewall, Optical Transmission Equipment, Data Storage
verified Customization Options
Customization from Samples, Customization from Designs, Full Customization, Minor Customization, Flexible customization
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
3 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2012-03-20
verified Export Year
13 Years
verified Main Markets
Domestic
verified Repeat Buyers Choice
< 10%
verified Number of Foreign Trading Staff
5
verified Overseas Agent/Branch
No
verified New Products Launched in Last year
No

Our Certifications, Standards & Industry Recognition

verified Cooperated with Fortune 500
No

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now