Oceanstor Sns2624 Sns3664 Sns3696e V200r001 Sns FC Storage Switches Server Network Storage

Product Details
Customization: Available
Storage Capacity: ≥32GB
Interface Type: USB 2.0 & USB 1.1
Still deciding? Get samples of US$ 10000/Piece
Request Sample
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 30 days
Low MOQ
The MOQ for the supplier's products is 1
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (8)
  • Oceanstor Sns2624 Sns3664 Sns3696e V200r001 Sns FC Storage Switches Server Network Storage
  • Oceanstor Sns2624 Sns3664 Sns3696e V200r001 Sns FC Storage Switches Server Network Storage
  • Oceanstor Sns2624 Sns3664 Sns3696e V200r001 Sns FC Storage Switches Server Network Storage
  • Oceanstor Sns2624 Sns3664 Sns3696e V200r001 Sns FC Storage Switches Server Network Storage
  • Oceanstor Sns2624 Sns3664 Sns3696e V200r001 Sns FC Storage Switches Server Network Storage
  • Oceanstor Sns2624 Sns3664 Sns3696e V200r001 Sns FC Storage Switches Server Network Storage
Find Similar Products
  • Overview
  • Product Description
  • Technical Specification
  • Product Display
  • Related Products
  • Company Profile
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
OceanStor SNS2624
Shape
Rectangular
Material
Plastic
Open Style
Opening
USB Type
Full-Fabric Architecture with Maximum 239 Switch
Color
Black
Function
Storage USB Disk, Encrypt USB Disk, Boot USB Disk, Antivirus USB Disk, Thermometer USB Disk, Music USB Disk
Security Check
Support Security Check
Model Number
Oceanstor Sns2624
Feature
High Efficiency/High Performance
Size
42.88 Cm*4.29 Cm*30.66 Cm
Weight
5.75 Kg (12.67 Lb) with One Integrated Power Suppl
Storage Altitude
up to 12 Km (39, 370 FT)
AC Input
90 V to 264 V, Maximum Input Current Is 2.2A
Power Consumption
76.52 W with All 24 Ports Populated with 32 Gbps S
Aggregate Bandwidth
768 Gbps End-to-End Full Duplex
Operating Humidity
10% to 85%
AC Input Line Frequency
47 Hz to 63 Hz
Management Access
10/100/1000 Mbps Ethernet (Rj-45), in-Band Over Fi
USB
One USB Port for System Log File Downloads or Firm
Classes of Service
Class 2, Class 3, Class F (Inter-Switch Frames)
Maximum Frame Size
2, 112-Byte Payload
Operating Environment
0 to 40
Transport Package
42.88 Cm*4.29 Cm*30.66 Cm
Specification
5.75 kg (12.67 lb) with one integrated power suppl
Trademark
for HUA WEI
Origin
Guangdong China

Product Description

 

Product Description

OceanStor SNS2624/SNS3664/SNS3696E FC Storage Switches

HUA-WEI OceanStor SNS2624/SNS3664/SNS3696E Switches are the purpose-built network infrastructure for mission-critical storage. Use Gen 6 Fibre Channel, Fabric Vision technology deliver unmatched 32 Gbps perfor-mance, increased scalability, and operational stability to ensure hyperscale virtualization, larger cloud infrastruc-tures, and growing flash-based storage environments.
Oceanstor Sns2624 Sns3664 Sns3696e V200r001 Sns FC Storage Switches Server Network Storage
Product Features:
 Powers up from 16 Gbps to 32 Gbps to deliver increased performance on demand. 32 Gbps links application performance barriers with up to 100 million IOPS
Provides an affordable storage switch that redefines simplicity and flexibility
Provides proactive, non-intrusive, real-time monitoring and alerting of storage IO health and performance with IO (support IO Insight, SNS2624 not support IO Insight ), the industry's first built-in device latency and IOPS monitor
Enables the seamless transition to next- generation NVMe flash arrays, without a disruptive rip and replace
Proactively monitors and optimizes the health and performance of individual Virtual Machines (VMs), and identifies anomalies with VM Insight
Increases resiliency by automatically discovering and recovering from common networking problems
Leverages Fabric Vision technology to simplify administration, quickly resolve problems, increase uptime, and reduce costsOceanstor Sns2624 Sns3664 Sns3696e V200r001 Sns FC Storage Switches Server Network Storage

Technical Specification

Model SNS2624 SNS3664 SNS3696E
System Architecture      
Number of ports Switch mode (default):8-port, 16-port, and 24-port configurations (8-port increment through Ports on Demand [PoD] license); Access Gateway default port mapping: 16 F_Ports, 8 N_Ports Switch mode (default): Minimum of 24 ports and maximum of 64 ports. Port numbers above minimum are enabled through 12-port SFP+ increments via Ports on Demand (PoD) licenses and through one 4-port QSFP PoD;
Access Gateway default port mapping: 40 SFP+ F_Ports, 8 SFP+ N_Ports
Offers a base configuration of 48 ports, two 24-port SFP+ PoD (Ports on Demand), and one 32-port QSFP PoD. The switch has a total of eight 32 Gbps QSPF ports. This allows users to grow from 48 ports to 128 ports.
Port types F_Port,E_Port,M_Port, D_Port (ClearLink Diagnostic Port) on 24 SFP+ ports; Access Gateway mode: F_Port and NPIV-enabled N_Port D_Port(ClearLink Diagnostic Port), E_Port,
EX_Port, F_Port, AE_Port; optional port-type control ;
Access Gateway mode: F_Port and NPIV-enabled N_Port
D_Port (ClearLink Diagnostic Port), E_Port, EX_Port, F_Port, AE_Port,
optional port-type control
Scalability Full-fabric architecture with a maximum of 239 switches
Certified maximum 6,000 active nodes; 56 switches, 19 hops in Fabric OS® fabrics; larger fabrics certified as required
Performance Fibre Channel: 4.25 Gbps line speed, full duplex; 8.5 Gbps line speed, full duplex;
14.025 Gbps line speed, full duplex;
auto-sensing of 4 Gbps, 8 Gbps, 16 Gbps, and 32 Gbps port speeds
Fibre Channel: 4.25 Gbps line speed, full duplex; 8.5 Gbps line speed, full duplex;
10.53 Gbps line speed, full duplex; 14.025 Gbps line speed, full duplex; 28.05 Gbps, full duplex; 112.2 Gbps, full duplex;
auto-sensing of 4, 8, 16, 32 Gbps port speeds and capable of supporting 128 Gbps speeds; 10 Gbps optionally programmable to fixed port speed
Fibre Channel: 4.25 Gbps line speed, full duplex; 8.5 Gbps line speed, full duplex;
10.53 Gbps line speed, full duplex; 14.025 Gbps line speed, full duplex; 28.05 Gbps, full duplex; 112.2 Gbps, full duplex;
auto-sensing of 4/8/10/16/32 Gbps port speeds and capable of supporting 128 Gbps speeds; 10 Gbps optionally programmable to fixed port speed.Auto-sensing of 4×32 / 4×16 / 4×8 / 4×4 Gbps speeds on the QSFP ports with FOS v8.2.0.
ISL Trunking Frame-based trunking with up to eight 32 Gbps ports per ISL trunk; up to 256 Gbps per ISL trunk
Exchange-based load balancing across ISLs with DPS included in Fabric OS
Frame-based trunking with up to eight 32 Gbps SFP+ ports per ISL trunk or up to two 128 Gbps QSFP ports per ISL trunk. Exchange-based load balancing across ISLs with DPS included in Fabric OS Frame-based trunking with up to eight 32 Gbps SFP+ ports per ISL trunk or up to two 128 Gbps QSFP ports per ISL trunk. Exchange-based load balancing across ISLs with DPS included in Fabric OS
Aggregate bandwidth 768 Gbps end-to-end full duplex 2 Tbps 4 Tbps
Maximum fabric latency Latency for locally switched ports is ≤ 900
ns (including FEC)
Latency for locally switched ports is < 780 ns (including FEC); compression is 1 µs per node Latency for locally switched ports is < 780 ns (including FEC);
Latency between port groups is 2.6 µs, cut-through routing at
32 Gbps between locally switched groups.compression is 1 µs per node
Maximum frame size 2,112-byte payload
Frame buffers 2,000 dynamically allocated 15,360 dynamically allocated 15,360 dynamically allocated
Classes of service Class 2, Class 3, Class F (inter-switch frames)
Data traffic types Fabric switches supporting unicast
USB One USB port for system log file downloads or firmware upgrades
Extension   Integrated optional 10 Gbps Fibre Channel for DWDM MAN connectivity Integrated optional 10Gbps Fibre Channel for DWDM MAN connectivity;
Fibre Channel, in-flight compression (LZO) and encryption (AES-GCM-256)
Management
Supported management

software
HTTP, SNMP v1/v3 (FE MIB, FC Manage-
ment MIB), SSH; Auditing, Syslog; Web Tools; Command Line Interface (CLI);SMI-S compliant; Administrative Domains; trial licenses for add-on capabilities
HTTP, SNMP v1/v3 (FE MIB, FC Manage-
ment MIB), SSH; Auditing, Syslog; NTP v3; Web Tools; Command Line Interface (CLI); SMI-S compliant; REST API; Administrative Domains; trial licenses for add-on capabilities
HTTP, SNMP v1/v3 (FE MIB, FC Manage-
ment MIB), SSH; Auditing, Syslog; NTP v3; Web Tools; Command Line Interface (CLI); SMI-S compliant; REST API; trial licenses for add-on capabilities
Management access 10/100/1000 Mbps Ethernet (RJ-45), in-band over Fibre Channel, serial port (RJ-45) and one USB port
Mechanical      
Enclosure Back-to-front airflow (non-port-side intake); power from back, 1U Front-to-back airflow; non-port-side exhaust; power from back, 1U
Back-to-front airflow; non-port-side intake; power from back, 1U
Front-to-back  airflow;  non-port-side exhaust; port-side intake; 2U
Back-to-front airflow; non-port-side intake; port-side exhaust; 2U
Size Width: 42.88 cm (16.88 in.)
Height: 4.29 cm (1.69 in.)
Depth: 30.66 cm (12.07 in.)
Width: 44 cm (17.32 in.)
Height: 4.39 cm (1.73 in.)
Depth: 35.56 cm (14 in.)
•Width: 44.0 cm (17.32 in.)
•Height: 8.67 cm (3.41 in.)
•Depth: 60.96 cm (24 in.)
System weight 5.75 kg (12.67 lb) with one integrated power supply, without transceivers 7.73 kg (17 lb) with two power supply FRUs, without transceivers 21.31 kg (47.00 lb) with two power supply FRUs,and three fan FRUs without transceivers
Environment      
Operating environment Temperature: 0°C to 40°C/32°F to 104°F Humidity: 10% to 85% (non-condensing)
Non-operating environment Temperature: -25°C to 70°C/-13°F to 158°F Humidity: 10% to 90% (non-condensing)
Operating altitude Up to 3,000 m (9,842 ft)
Storage altitude Up to 12 km (39,370 ft)

Shock                                            
Operating: Up to 20 G, 6 ms half-sine
Non-operating: Half sine, 33 G 11 ms,
3G axis
Operating: Up to 20 G, 6 ms half-sine Non-operating: Half-sine, 33 G 11 ms, 3/eg axis Operating: Up to 20 G, 6 ms half-sine Non-operating: Half-sine, 33 G 11 ms, 3/eg axis
Vibration Operating: 0.5 g sine, 0.4 grms random, 5 Hz to 500 Hz
Non-operating: 2.0 g sine, 1.1 grms random, 5 Hz to 500 Hz
Heat dissipation 24 ports at 215 BTU/hr 64 ports at 716 BTU/hr 128 ports at 3,512 BTU/hr
Power      
Power supply/Fan Base switch includes a single, fixed power supply with four integrated system cooling fans Dual, hot-swappable redundant power supplies with integrated system cooling fans Dual, hot-swappable redundant power supplies with integrated system cooling fans
Three hot-swappable redundant Fans
AC input 90 V to 264 V,
Maximum input current is 2.2A
90 V to 264 V-3.5 A 90 V to 264 V-12 A
AC input line frequency 47 Hz to 63 Hz    
Power consumption 76.52 W with all 24 ports populated with 32 Gbps SWL optics
55.83 W for idle configuration (all optics loaded but not initialized)
204 W with all 64 ports populated with 48×32 Gbps SFP+ SWL optics and 4× (4×32 Gbps) QSFP SWL optics
85 W for empty chassis with no optics
Maximum 942 W with all 128 ports operating at 32 Gbps (96 ports populated with 32 Gbps SWL optics and 8 QSFP ports populated with 4×32 Gbps SWL optics)
Maximum of 495 W for empty chassis with no optics in idle configuration

Product Display

Oceanstor Sns2624 Sns3664 Sns3696e V200r001 Sns FC Storage Switches Server Network Storage
Oceanstor Sns2624 Sns3664 Sns3696e V200r001 Sns FC Storage Switches Server Network StorageOceanstor Sns2624 Sns3664 Sns3696e V200r001 Sns FC Storage Switches Server Network Storage

Related Products

Oceanstor Sns2624 Sns3664 Sns3696e V200r001 Sns FC Storage Switches Server Network StorageOceanstor Sns2624 Sns3664 Sns3696e V200r001 Sns FC Storage Switches Server Network StorageOceanstor Sns2624 Sns3664 Sns3696e V200r001 Sns FC Storage Switches Server Network Storage

Company Profile

Oceanstor Sns2624 Sns3664 Sns3696e V200r001 Sns FC Storage Switches Server Network Storage
Oceanstor Sns2624 Sns3664 Sns3696e V200r001 Sns FC Storage Switches Server Network StorageOceanstor Sns2624 Sns3664 Sns3696e V200r001 Sns FC Storage Switches Server Network Storage

Our Advantages

The product is 100% genuine and has sufficient stock in stock;
Price discounts and fast delivery;
After sales service guarantee; Support sample and customization services.

FAQ

Q: Are you a trading company or a manufacturer? Can I use our own logo and label?
A: We are a trading company that provides domestic and international trade services. We also provide OEM/OEM services.

Q: What are the guarantees for product quality?
A: We have professional engineers who test each piece of equipment before shipment to ensure that the shipped products are in good condition.

Q: How did you resolve a defective product when I received it?
A: We have professional personnel to help you solve the problem. If the product is defective, we usually offer you a return, refund, or replacement of the defective product.

Q: What is your payment method and delivery time?
A: We accept credit cards, wire transfers, PayPal, and other payment methods. We also support fast shipping within 72 hours.

Q: What is the MOQ and how long is the warranty period?
A: The minimum order quantity for normal products is 1, and the product warranty period is usually 1 year.

Oceanstor Sns2624 Sns3664 Sns3696e V200r001 Sns FC Storage Switches Server Network Storage

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier