Customization: | Available |
---|---|
Communication Mode: | Full-Duplex & Half-Duplex |
Type: | Ethernet Switch |
Still deciding? Get samples of US$ 50000/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item | CloudEngine 8865-4C |
Switching capacity | 16 Tbps |
Packet forwarding rate | 2400 Mpps |
Buffer | 64MB |
Air duct type | Standard front-to-back or back-to-front airflow |
Device virtualization | M-LAG |
Port | Jumbo frames |
Network virtualization | VXLAN routing and VXLAN bridging |
BGP-EVPN | |
SDN | iMaster NCE-Fabric |
Network convergence | PFC and AI ECN |
RDMA and RoCE (RoCE v1 and RoCE v2) | |
Programmability | OpenFlow |
OPS programming | |
Traffic analysis | NetStream |
VLAN | Access, trunk, and hybrid ports |
Default VLAN | |
MAC address table | Automatic MAC address learning and aging |
Static, dynamic, and blackhole MAC address entries | |
Source MAC address filtering | |
MAC address learning limiting based on ports and VLANs | |
IP routing | IPv4 dynamic routing protocols such as RIP, OSPF, IS-IS, and BGP |
IPv6 dynamic routing protocols such as RIPng, OSPFv3, IS-ISv6, and BGP4+ | |
IPv6 | VXLAN over IPv6 |
IPv6 VXLAN over IPv4 | |
IPv6 neighbor discovery (ND) | |
Path MTU discovery (PMTU) | |
TCP6, IPv6 ping, IPv6 tracert, IPv6 socket, UDP6, and raw IPv6 | |
Multicast | Multicast routing protocols such as IGMP, PIM-SM, and MSDP |
IGMP snooping and IGMP proxy | |
IPv6 Layer 3 multicast and configuration of both Layer 2 and Layer 3 multicast services | |
Fast leaving of multicast member interfaces | |
Multicast traffic suppression | |
Multicast NAT | |
Reliability | LACP |
STP, RSTP, VBST, and MSTP | |
BPDU protection | |
Smart link and multi-instance | |
Hardware-based Bidirectional Forwarding Detection (BFD), with a minimum packet sending interval of 3.3 ms |
|
VRRP, VRRP load sharing, and BFD for VRRP | |
BFD for BGP, IS-IS, OSPF, and static routing | |
BFD for VXLAN | |
Traffic classification based on Layer 2 headers, Layer 3 protocols, and Layer 4 protocol priorities | |
QoS | ACL, CAR, re-marking, and scheduling |
Queue scheduling modes such as PQ, DRR, and PQ+DRR | |
Congestion avoidance mechanisms such as WRED and tail drop | |
Traffic shaping | |
IEEE 1588v2 (PTP) | |
Intelligent O&M | Network-wide path detection |
Telemetry | |
Enhanced ERSPAN | |
In-situ Flow Information Telemetry (IFIT) | |
Packet Event: packet loss visualization and ultra-long latency visualization | |
Statistics collection on the buffer microburst status | |
VXLAN OAM: VXLAN ping and VXLAN tracert | |
Intelligent lossless network | PFC deadlock prevention |
AI ECN | |
ECN Overlay | |
Enhanced NSLB | |
Configuration and maintenance | Terminal login through the console port, Telnet, and SSH |
Network management protocols, such as SNMPv1/v2/v3 | |
File upload and download through FTP and TFTP | |
Boot Read-Only Memory (BootROM) upgrade and remote online upgrade | |
Hot patching | |
User operation logs | |
Configuration rollback | |
ZTP | |
Security and management | MACsec |
Command line authority control based on user levels, preventing unauthorized users from using commands | |
Defense against DoS, ARP, and ICMP attacks | |
Port isolation, port security, and sticky MAC | |
Binding of the IP address, MAC address, port ID, and VLAN ID | |
Authentication methods, including AAA, LDAP, RADIUS, and HWTACACS | |
RMON | |
Dimensions (H x W x D) | 88.1 mm x 442.0 mm x 600.0 mm |
Weight in full configuration | 16.54 kg |
Environment requirements | Operating temperature: 0°C to 40°C (0 m to 1800 m) Storage temperature: -40°C to +70°C Relative humidity: 5% RH to 95% RH (noncondensing) |
Operating voltage | 600 W AC and 240 V DC power module: AC: 90 V AC to 290 V AC, 45 Hz to 65 Hz; DC: 190 V DC to 290 V DC 1200 W DC power module: -38.4 V DC to -72 V DC; 40 V DC to 57 V DC |
Typical power consumption | CE8865-4C (configured with four CE88-D16CQ-H cards): 650W (100% load, 32 x 100G copper cables, room temperature, dual AC power supplies) 728W (100% load, 32*100G port short-distance optical module, normal temperature, dual AC power supplies) CE8865-4C (configured with four CE88-D10CQ-H cards): 315W (100% load, 20 x 100G copper cables, normal temperature, dual AC power supplies) 338W (100% load, 20 x 200G copper cables, room temperature, dual AC power supplies) 345W (100% load, 20*100G port short-distance optical module, normal temperature, dual AC power supplies) 420W (100% load, 20*200G short-distance optical modules, room temperature, dual AC power supplies) CE8865-4C (configured with four CE88-D8YS4DQ-H cards): 306W (100% load, 8*400G+16*25G copper cables, room temperature, dual AC power supplies) 406W (100% load,8*400G+16*25G short-distance optical modules, normal temperature, dual AC power supplies) CE8865-4C (configured with four CE88-D24YS2CQ-H cards): 305W (100% load, 48*25G+4*100G copper cables, room temperature, dual AC power supplies) 338W (100% load,48*25G+4*100G short-distance optical modules, normal temperature, dual AC power supplies) CE8865-4C (configured with four CE88-D24T2CQ-H cards): 381W (100% load, 48*10G electrical ports + 4*100G copper cables, room temperature, dual AC power supplies) 388W (100% load, 48*10G electrical modules+4*100G short-distance optical modules, normal temperature, dual AC power supplies) |
Item | Value |
Maximum number of MAC address entries | 640K |
Maximum number of routes (FIB IPv4/IPv6) | 1.5M/750K |
ARP size | 128K |
Maximum number of VRFs | 4096 |
IPv6 ND table size | 128K |
Maximum number of VRRP groups | 1024 |
Maximum number of ECMP paths | 128 |
Maximum number of VXLAN bridge domains | 16K |
Maximum number of BDIF interfaces | 16K |
Maximum number of virtual tunnel endpoints (VTEPs) | 16K |
Maximum number of LAGs | 1024 |
Maximum number of links in a LAG | 256 |
Maximum number of MSTIs | 1000 |
Maximum number of VLANs where VBST can be configured | 640K |
Device | Description |
CE8865-4C | CE8865-4C Mainframe (With 4 Subcard Slots, Without Fan and Power Modules) |
CE8865-4C-B | CE8865-4C Mainframe (With 4 Subcard Slots, 2*AC Power Modules, 3*Fans, Port-side Intake) |
CE8865-4C-F | CE8865-4C Mainframe (With 4 Subcard Slots, 2*AC Power Modules, 3*Fans, Port-side Exhaust) |
Fan module | |
Model | Description |
FAN-180E-B | Fan box (B,FAN panel side exhaust) |
FAN-180E-F | Fan box (F,FAN panel side intake) |
Power supply modules | |
Model | Description |
PAC2KS12-PB | 2000W AC&240V DC Power Module (Back to Front,Power panel side exhaust) |
PAC1K8S12-PF | 1800W AC&240V DC Power Module (Front to Back,Power panel side intake) |
PDC2K2S12-PB | 2200W DC Power Module (Back to Front, Power panel side exhaust) |
PDC2K2S12-PF | 2200W DC Power Module (Front to Back, Power panel side intake) |
PHD2KS12-PB | 2000W HVDC Power Module (Back to Front, Power panel side exhaust) |
Hardware RTU | |
CE88-RTU-U2CQ | 100GE upgraded to 200GE |
CE88-RTU-U24YS | 25GE upgraded to 50GE |
Software | |
N1-CE88LIC-CFFD | N1-CloudFabric Foundation SW License for CloudEngine 8800 |
N1-CE88CFFD-SnS1Y | N1-CloudFabric Foundation SW License for CloudEngine CE8800-SnS-Year |
N1-CE88LIC-CFAD | N1-CloudFabric Advanced SW License for CloudEngine 8800 |
N1-CE88CFAD- SnS1Y | N1-CloudFabric Advanced SW License for CloudEngine CE8800-SnS-Year |
N1-CE88LIC-CFPM | N1-CloudFabric Premium SW License for CloudEngine 8800 |
N1-CE88CFPM- SnS1Y | N1-CloudFabric Premium SW License for CloudEngine 8800-SnS-Year |
N1-CE88UPG-F-A | N1-CloudEngine 8800 Upgrade SW License:Foundation to Advanced |
N1-CE88UGFA- SnS1Y | N1-CloudEngine 8800 Upgrade SW License:Foundation to Advanced-SnS-Year |
N1-CE88UPG-A-P | N1-CloudEngine 8800 Upgrade SW License:Advanced to Premium |
N1-CE88UGAP- SnS1Y | N1-CloudEngine 8800 Upgrade SW License:Advanced to Premium-SnS-Year |
N1-CE88LIC-AFRD-2 | N1-CloudEngine 8800 AI Fabric RDMA Application Acceleration Function 2 |
N1-CE88AFRD2- SnS1Y | N1-CloudEngine 8800 AI Fabric RDMA Application Acceleration Function 2-SnS-Year |
N1-CE168LIC-HPC | N1-CE88LIC-HPC,N1-CloudEngine 16800 AI Fabric Value-added Package for the HPC Scenarios |
N1-CE168HPC-SnS1Y | N1-CloudEngine 16800 AI Fabric Value-added Package for the HPC Scenarios-SnS-1 Year, |
N1-CE88LIC-AI | N1-CloudEngine 8800 Value-added Package for the AI Scenarios |
N1-CE88AI-SnS1Y | N1-CloudEngine 8800 Value-added Package for the AI Scenarios-SnS Year |
N1-CE88LIC-SEC | N1-CloudEngine 8800 Security Function |
N1-CE88SEC-SnS1Y | N1-CloudEngine 8800 Security Function-SnS-Year |
N1-CE-F-LIC-MDCA | N1-CloudEngine Data Center Switch Multi-cloud Multi-DC Value-added Package - Fixed |
N1-CEFMDCA - SnS1Y | N1-CloudEngine Data Center Switch Multi-cloud Multi-DC Value-added Package, Per Fixed device- SnS-Year |
N1-CE-F-LIC-DM | N1-CloudEngine Digital Map Basic Function-Fixed |
N1-CEMDF-SnS1Y | N1-CloudEngine Digital Map Function |
N1-CE-LIC-AFP100VM | N1-CloudEngine Specified Flow Analysis Value-added Package Per 100 VM |
N1-CEAFP100VM-SnS1Y | N1-CloudEngine Specified Flow Analysis Value-added Package Per 100 VM-SnS-Year |
N1-CE88LIC-TCPAC | N1-CE88LIC-TCPAC,N1-CloudEngine 8800 Value-added Package for the TCP Acceleration Scenarios |
N1-CE-LIC-XFLOW20G | N1-CloudEngine xFlow Intelligent Full-flow Analysis |
The product is 100% genuine and has sufficient stock in stock;
Price discounts and fast delivery;
After sales service guarantee; Support sample and customization services.
Q: Are you a trading company or a manufacturer? Can I use our own logo and label?
A: We are a trading company that provides domestic and international trade services. We also provide OEM/OEM services.
Q: What are the guarantees for product quality?
A: We have professional engineers who test each piece of equipment before shipment to ensure that the shipped products are in good condition.
Q: How did you resolve a defective product when I received it?
A: We have professional personnel to help you solve the problem. If the product is defective, we usually offer you a return, refund, or replacement of the defective product.
Q: What is your payment method and delivery time?
A: We accept credit cards, wire transfers, PayPal, and other payment methods. We also support fast shipping within 72 hours.
Q: What is the MOQ and how long is the warranty period?
A: The minimum order quantity for normal products is 1, and the product warranty period is usually 1 year.