NetEngine 5000E core routers
NE5000E CCC-A CR5B0BKPCD52: Assembling Components,NetEngine5000E,CR5B0BKPCD01,NE5000E CCC-A Cluster 380V HVDC Chassis
Hua wei NetEngine 5000E core routers are designed to be used as an enterprise backbone network node, metro network core node, Data Center Interconnect (DCI) node, or international gateway. Offering high capacity, high reliability, intelligence, and energy-saving capabilities, NetEngine 5000E support single chassis, back-to-back chassis, and multi-chassis cluster modes: this allows on-demand expansion, enabling enterprises to handle rapid Internet traffic growth and future service development with ease.
1.Hardware Specifications
Item |
Specification |
---|---|
Cabinet installation standards |
The chassis can be installed in a standard 19-inch 1000 mm deep cabinet. By default, the customized A610 cabinet is used. |
Dimensions without packaging (H x W x D) [mm(in.)] |
1955 mm x 442 mm x 830 mm (76.97 in. x 17.4 in. x 32.68 in.) |
Chassis height [U] |
44 U |
Weight without packaging [kg(lb)] |
205 kg (451.95 lb) |
Weight without packaging (full configuration) [kg(lb)] |
400G 2+8 cluster: 485 kg (1069.42 lb) 1T 2+8 cluster: 506 kg (1115.73 lb) 1.6T 2+8 cluster: 528.4 kg (1164.90 lb) |
Typical power consumption (with configuration) [W] |
400G 2+2 cluster:2310 W 400G 2+4 cluster:3190 W 400G 2+8 cluster:5910 W 1T 2+2 cluster:3500 W 1T 2+4 cluster:4900 W 1T 2+8 cluster:9200 W 1.6T 2+2 cluster: 7450 W 1.6T 2+4 cluster: 8520 W 1.6T 2+8 cluster: 16230 W |
Typical heat dissipation (with configuration) [BTU/hour] |
400G 2+2 cluster:7494.6 BTU/hour 400G 2+4 cluster:10349.7 BTU/hour 400G 2+8 cluster:19174.5 BTU/hour 1T 2+2 cluster:11355.5 BTU/hour 1T 2+4 cluster:15897.7 BTU/hour 1T 2+8 cluster:29848.7 BTU/hour 1.6T 2+2 cluster:24170.9 BTU/hour 1.6T 2+4 cluster:27642.5 BTU/hour 1.6T 2+8 cluster:52656.9 BTU/hour |
MTBF [year] |
15.06 year |
MTTR [hour] |
0.5 hour |
Availability |
0.99999 |
Power supply mode |
AC/HVDC built-in |
Maximum number of power chassis inputs |
Double-plane chassis: (4 channels/PEM) x 5 PEMs = (1 channel/PM) x 4 PMs x 5 PEMs = 20 channels |
Rated input voltage [V] |
AC: 200 V to 240 V High-voltage DC: 240 V/380 V |
Input voltage range [V] |
AC: Maximum range: 180 V to 264 V Rated voltage of the 220 V power grid: 200 V to 240 V High-voltage DC: 192 V to 400 V |
Maximum input current [A] |
AC: 16 A per module High-voltage DC: 14 A per module |
Maximum input cable size [mm²] |
AC: C19 cable in standard configuration High-voltage DC: 2.5 mm² |
Front-end circuit breaker/fuse [A] |
AC: 16 A per module High-voltage DC: 14 A per module |
Number of slots |
22 |
Number of service board slots |
0 |
Redundant MPUs |
1:1 |
Redundant Switch fabrics |
7+1 |
Redundant power supply |
N+N |
Redundant fans |
The fan tray assemblies are located in the upper and lower areas at the rear of the chassis. Each area is as follows: (400G/1T configuration) Two fan tray assemblies, allowing the device to work properly for a short time at 40ºC if a single fan module fails. Three fan assemblies are configured for 1.6T, allowing the device to work properly for a short time at 40ºC if a single fan module fails. |
Long-term operating temperature [°C(°F)] |
0°C to 40°C(32°F to 104°F) |
Short-term operating temperature [°C(°F)] |
-5°C to 50°C (23°F to 122°F) |
Restriction on the operating temperature variation rate [°C(°F)] |
≤ 0.5°C/min (32.9°F/min), non-condensing |
Storage temperature [°C(°F)] |
-40°C to +70°C (-40°F to +158 °F) |
Long-term operating relative humidity [RH] |
5% RH to 85% RH, non-condensing |
Short-term operating relative humidity [RH] |
5% RH to 95% RH, non-condensing |
Storage relative humidity [RH] |
5% RH to 95% RH, non-condensing |
Long-term operating altitude [m(ft.)] |
3000M @ 40°C |
Storage altitude [m(ft.)] |
< 5000 m (16404.20 ft.) |
Description |
Model |
---|---|
Assembling Components,NetEngine5000E,CR5B0BKPCD02,NE5000E CCC-A Cluster 220V AC/240V DC Chassis |
CR5B0BKPCD51 |
Assembling Components,NetEngine5000E,CR5B0BKPCD01,NE5000E CCC-A Cluster 380V HVDC Chassis |
CR5B0BKPCD52 |
NE5000E CCC-A Cluster AC and HVDC Chassis B |
CR5B0BKPCA53 |
NE5000E CCC-A Cluster DC Chassis B |
CR5B0BKPCD53 |
Assembling Components,NetEngine5000E,CR5B0BKPCA50,NE5000E CCC-A Cluster AC Chassis |
CR5B0BKPCA50 |
Assembling Components,NetEngine5000E,CR5B0BKPCD50,NE5000E CCC-A Cluster DC Chassis |
CR5B0BKPCD50 |
The product is 100% genuine and has sufficient stock in stock;
Price discounts and fast delivery;
After sales service guarantee; Support sample and customization services.
Q: Are you a trading company or a manufacturer? Can I use our own logo and label?
A: We are a trading company that provides domestic and international trade services. We also provide OEM/OEM services.
Q: What are the guarantees for product quality?
A: We have professional engineers who test each piece of equipment before shipment to ensure that the shipped products are in good condition.
Q: How did you resolve a defective product when I received it?
A: We have professional personnel to help you solve the problem. If the product is defective, we usually offer you a return, refund, or replacement of the defective product.
Q: What is your payment method and delivery time?
A: We accept credit cards, wire transfers, PayPal, and other payment methods. We also support fast shipping within 72 hours.
Q: What is the MOQ and how long is the warranty period?
A: The minimum order quantity for normal products is 1, and the product warranty period is usually 1 year.