Universal Service Router Ne40e-X16A Cr5p16basa76 AC Power Supply Chassis Mpu Sfu Port Netengine40e Network Router

Product Details
Customization: Available
Type: Wireless
Network Site: Intermediate Node Routers
Still deciding? Get samples of US$ 50000/Piece
Request Sample
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 30 days
Low MOQ
The MOQ for the supplier's products is 1
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (8)
  • Universal Service Router Ne40e-X16A Cr5p16basa76 AC Power Supply Chassis Mpu Sfu Port Netengine40e Network Router
  • Universal Service Router Ne40e-X16A Cr5p16basa76 AC Power Supply Chassis Mpu Sfu Port Netengine40e Network Router
  • Universal Service Router Ne40e-X16A Cr5p16basa76 AC Power Supply Chassis Mpu Sfu Port Netengine40e Network Router
  • Universal Service Router Ne40e-X16A Cr5p16basa76 AC Power Supply Chassis Mpu Sfu Port Netengine40e Network Router
  • Universal Service Router Ne40e-X16A Cr5p16basa76 AC Power Supply Chassis Mpu Sfu Port Netengine40e Network Router
  • Universal Service Router Ne40e-X16A Cr5p16basa76 AC Power Supply Chassis Mpu Sfu Port Netengine40e Network Router
Find Similar Products
  • Overview
  • Product Description
  • Technical specification
  • Product display
  • Related product
  • Company Profile
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
02350AQR CR5P16BASA76 NE40E-X16A
Transfer Rate
10/100/1000Mbps
Firewall
Without Firewall
Ports
22
Port Structure
Other
Application
Enterprise
Network
Wireless LAN, Wired LAN, Onvif, Sdk, TCP
Performance
Line-Rate Router
Architecture
Netengine40e Universal Service Router
Dimensions (H X W X D)
(40 U) 1778 mm X 442 mm X 750 mm with Cable Trays
Chassis Main Body Dimensions (H X W X D)
(40 U) 1778 mm X 442 mm X 650 mm
Weight(Empty)
DC: 120.5 Kg (265.7 Lb) ; &AC: 111.7 Kg
Weight (Full Configuration)
DC:399.4 Kg;Hvdc&AC:395.1 Kg;2t Bundle DC:461.3kg
Switching Capacity
50.32 Tbps (Lpui-1t) ; 81.92 Tbps (Lpui-2t)
Forwarding Performance
5600 Mpps (Lpuf-240)
Typical Power Consumption
7720 W (Fully Configured with Lpuf- 240s)
Number of Slots Supported
22
Port Capability
Supports Various Interface Types (E1, Ge, Fe,Wan,L
Operating Temperature
0 to 40
Redundant Mpus
1:1
Mttr
0.5 Hours
DC Input Voltage
-48 V/ -60 V
AC Input Voltage
180 V to 264 V
Storage Altitude
Less Than 5000 M (16404 FT.)
Transport Package
(40 U) 1778 mm X 442 mm X 750 mm
Specification
399.4 kg
Trademark
for HUA WEI
Origin
Guangdong, China

Product Description

 

Product Description

Hua wei NetEngine40E Universal Service Router (NE40E)

NE40E-X16(02350AQR CR5P16BASA76):
Basic Configuration (Including NE40E-X16A Chassis, 2 MPUs, 4 SFUs(480G),10 AC Power,4 Fan Tray, without Software Charge and Document)

Hua wei NetEngine40E Universal Service Router (NE40E) Series routers are high-end network products developed by Hua wei. The NE40E Series includes the NE40E-X3, NE40E-X8, NE40E-X16, NE40E-X3A, NE40E-X8A and NE40E-X16A.

The NE40E Series routers are usually deployed at core nodes on enterprise wide area networks (WANs), access nodes on large-scale enterprise networks, interconnection and aggregation nodes on campus networks, and edge nodes on large-scale Internet Data Center (IDC) networks. The NE20E, NE40E, and NE5000E can work together to provide a complete hierarchical IP network solution.

Universal Service Router Ne40e-X16A Cr5p16basa76 AC Power Supply Chassis Mpu Sfu Port Netengine40e Network RouterFeatures:
The NE40E Series routers run on the Versatile Routing Platform (VRP) operating system and use hardware-based forwarding and non-blocking switching technologies. Based on distributed hardware forwarding, non-blocking 
switching technologies, distributed Clos architecture, and industry-leading 2T bps platform, the NE40E Series routers have the following features:


Support for 1T routing line cards in each slot, with excellent compatibility with currently used line cards to protect carriers' investments to the largest extent.
Line speed forwarding capabilities, industry-leading reliability, excellent scalability, a well-designed quality of service (QoS) mechanism, and strong service processing capabilities.
Powerful service access and aggregation capabilities and various features, such as Layer 2 virtual private network (L2VPN), L3VPN, multicast, multicast VPN (MVPN), and Multiprotocol Label Switching - Traffic Engineering (MPLS-TE).
Various service features, such as IP Security (IPSec), Network Address Translation (NAT), and NetStream.
Support for IPv6 and smooth transition from IPv4 to IPv6.

The NE40E can be flexibly deployed at the edge or core of IP or MPLS networks, simplifying network structure. With its ability to provide an extensive range of services and reliable service quality, the NE40E is driving IP and MPLS bearer networks to develop greater broadband capacity and to become more secure, more intelligent, and more service-oriented.
Universal Service Router Ne40e-X16A Cr5p16basa76 AC Power Supply Chassis Mpu Sfu Port Netengine40e Network Router
 

Technical specification

1.Features
Features Description
Powerful Service Support
Port capability The NE40E supports various interface types (E1, POS, CPOS, FE, GE, 10GE-LAN/WAN, 25GE, 40GE, 50GE, and 100GE) and high-density fixed ports to provide access and aggregation WAN services as well as Ethernet multi-service transmission platform (MSTP) aggregation services, satisfying various service requirements. Support dedicated interface for out-of-band management 10/100/1000 and RJ-45 interface for time synchronization.
Routing RIP, RIPng, OSPF, OSPFV3, IS-IS, IS-ISV6, BGP, BGPv6, Static routing, IPv4 Multicast, IPv6 Multicast, Multicast static, etc
IPv4 TCP/IP, for example, ICMP, IP, TCP, UDP, Socket (TCP/UDP/RAW IP), ARP Static DNS, DNS Client ,FTP Server, FTP Client ,TFTP Client, DHCP Relay ,DHCP Server ,Ping ,Tracert ,NQA ,IP policy-based routing,
Forwarding next hop based on traffic IP policy-based route load balancing
The QinQ interface (QinQ termination and dot1q termination) supports IPv4 load balancing.
Enabling and disabling the rapid ping reply function based on interface boards
Forcible fragmentation for packets with length greater than MTU and DF enabled MPLS-in-UDP tunnel egress
PIM Multicast
IPv6 IPv6(ND),Path MTU (PMTU),TCP6, Ping IPv6, Tracert IPv6, Socket IPv6, DHCPv6 Relay, Static IPv6 DNS, TFTP IPv6 Client,IP policy-based routing, IPv6 ND fast reply,PIM Multicast
L2VPN PWE3/VLL,VPLS,EVPN,EVPN L3VPN,VxLAN,L2TP
L3VPN CE routers can access the L3VPN through L3 interfaces. MP-BGP, RSVP-TE P2MP
Support static routes between CE and PE, BGP, RIP, OSPF and ISIS
Inter-AS VPN, including RFC2547bis option A.
Inter-AS VPN, including RFC2547bis option B
Inter-AS VPN, including RFC2547bis option C
NG-MVPN
IPv6 VPN
HoVPN
Seamless MPLS
BGP LSP entropy label
Redirect to VPN
L3VPN PIPE/Uniform mode
L3VPN Statistics
SRv6 SRv6-BE,SRv6 Policy,SRv6 egress protection
VAS BNG/BRAS,NAT/CGN,IPSec,MACSec
Clock Physical layer synchronization,1588v2 Optional support of ITU-T G8273.2 Class C
OAM iFIT IPFPM NQA TWAMP BFD
MPLS OAM MPLS-TP OAM VRRP
Ethernet OAM 802.3ah Y1731
Ethernet LPT
Bit-error-triggered protection switching
QoS QPPB,Differ-Serv,HQoS,Redirection

2.Product Specifications
Item NE40E-X3 NE40E-X8 NE40E-X16 NE40E-X3A NE40E-X8A NE40E-X16A
Switching capacity 1.08 Tbps 7.08 Tbps
(LPUF- 240/LPUI-240)
12.58 Tbps
(LPUF- 240/LPUI-240)
2.76 Tbps l 25.16 Tbps (LPUI-1T)
l 51.2 Tbps (LPUI-2T)
l 50.32 Tbps (LPUI-1T)
l 81.92 Tbps (LPUI-2T)
Forwarding performance l 105 Mpps
(LPUF-51)

l 360 Mpps
(LPUF-120)
2800 Mpps (LPUF-240) 5600 Mpps (LPUF-240) 900 Mpps (LPUF-200) 2800 Mpps (LPUF-240) 5600 Mpps (LPUF-240)
Number of slots supported 5 11 22 5 12 22
Number of interface board slots supported Redundant MPUs 1:1
Redundant Switch fabrics N/A 2+1 3+1 N/A 3+1 3+1
MTBF 27.44 years 21.91 years 21.66 years 22.85 years 22.32 years 22.33 years
MTTR 0.5 hours
Availability 0.99999792 0.999997395 0.999997365 0.999997502 0.999997443 0.9999974444
Dimensions (H x W x D) l DC: (4 U)
175 mm x442 mm x650 mm (6.89 in. x
17.40 in. x25.59 in.)

l AC: (5 U)
220 mm x442 mm x650 mm
(8.66 in. x17.40 in. x 25.59 in.)
l (14 U) 620mm x 442
mm x 650mm (24.41
in. x 17.40in. x 25.59 in.)(Chassis main body)
l (14 U) 620mm x 442
mm x 770mm (24.41
in. x 17.40in. x 30.31 in.)(Dimens ions of the chassis body together with cable trays and front and back attachment s)
l (32 U) 1420mm x 442
mm x 650mm (55.91
in. x 17.40in. x 25.59 in.) (Chassis main body)
l (32 U) 1420mm x 442
mm x 770mm (55.91
in. x 17.40in. x 30.31 in.) (Dimension s of the chassis body together with cable trays and front and back attachment s)
l (6 U) 264mm x 442mm x 710mm (10.39in. x 17.40
in. x 27.95 in.) (Chassis main body)
l DC: (6 U)
264 mm x442 mm x758 mm
(10.39 in. x17.40 in. x29.84 in.)
(Dimension s of the chassis body together with cable trays and front and back attachment s)
l AC: (6 U)
264 mm x442 mm x770 mm
(10.39 in. x17.40 in. x30.31 in.)
(Dimension s of the chassis body together with cable trays and front and back attachment s)
l (21 U) 930mm x 442mm x 650
mm (36.61in. x 17.40in. x 25.59 in.) (Chassis main body)
l (21 U) 930mm x 442mm x 750
mm (36.61in. x 17.40in. x 29.53 in.) (Dimension s of the chassis body together with cable trays and front and back attachment s)
l [2T bundle](21U)
930 mm
x 442 mm x 941 mm
(36.61 in. x17.40 in. x37.05 in.)
(Dimension s of the chassis body together with cable trays and front and back attachment s and noise reduction module)
l (40 U) 1778mm x 442
mm x 650mm (70.00in. x 17.40in. x 25.59 in.) (Chassis main body)
l (40 U) 1778mm x 442mm x 750mm (70.00in. x 17.40
in. x 29.53 in.) (Dimension s of the chassis body together with cable trays and front and back attachments)
l [2T bundle](40 U)
1778
mm x 442mm x 946
mm (70.00in. x 17.40
in. x 37.24 in.) (Dimension s of the chassis body together with cable trays and front and back attachment s)
Weight (empty) l DC: 12 kg
(26.46 lb)
l AC: 20 kg
(44.1 lb)
25.8 kg (56.89
lb) (without filler panels)
69.6 kg
(153.47 lb)
(without filler panels)
26 kg (57.33
lb)
l DC: 68.1 kg (150.16 lb)
(without filler panels)
l HVDC&AC:
63.7 kg(140.46 lb)
(without filler panels)
l DC: 120.5kg (265.7
lb) (without filler panels)
l HVDC&AC:
111.7 kg(246.3 lb)
(without filler panels)
Weight (full configuration) l DC: 42 kg (92.61 lb)
l AC: 52 kg (114.66 lb)
136 kg (299.88 lb) 279 kg (615.2 lb) l DC: 72.1 kg (158.98 lb)
l AC: 74.7 kg (164.71 lb)
l [1T bundle] DC:209 kg (460.85 lb)
l [1T bundle]HVDC&AC:206.5 kg (455.33 lb)
l [2T bundle]DC:242kg (533.51 lb)
l [2T bundle]AC&HVDC:234.4kg(516.76 lb)
l [1T bundle] DC:399.4 kg (880.68 lb)
l [1T bundle] HVDC&AC:395.1 kg (871.2 lb)
l [2T bundle] DC:461.3kg(1017.0 lb)
l [2T bundle] HVDC&AC:453.3kg(999.34 lb)
Cabinet installation standard Can be installed in a standard 19"800 mm-deep cabinet. A Hua wei 2.2 m- high N68E cabinet is used by default. Can be installed in a standard 19"800 mm-deep cabinet. A Hua wei 2.2 m- high N68E cabinet is used by default. Can be installed in a standard 19"800 mm-deep cabinet. A Hua wei 2.2 m- high N68E cabinet is used by default. Can be installed in a standard 19"
800 mm-deep cabinet. A Hua wei 2.2 m- high N68E cabinet is used by default.
l Can be installed in a standard 19" 800mm-deep cabinet. A Hua wei 2.2 m-high N68E
cabinet is used by default.

l [2T bundle] Can be installed in a standard 19" 1000mm-deep cabinet,part number is 02115109( CR5B0N61 0E60)
l Can be installed in a standard 19" 800
mm-deep cabinet. A Hua wei 2.2 m-high N68E cabinet is used by default.

l [2T bundle] Can be installed in a standard 19" 1000mm-deep cabinet,part number is 02115109( CR5B0N61 0E60)
Typical power consumption l DC: 800 W
(fully configured
with LPUF- 51s)
l AC: 950 W
(fully configured with LPUF- 51s)

l DC: 920 W
(fully configured with LPUF- 120s)

l AC: 1070
W (fully configured with LPUF- 120s)
3220 W (fully configured with LPUF-240s) 6210 W (fully configured with LPUF-240s) 1120 W (fully configured with LPUF-200s) l 4110 W
(fully configured
with LPUF- 240s)
l 4770 W
(fully configured with LPUF- 480s)

l 6520 W
(fully configured with LPUI- 1Ts)

l 11100 W
(fully configured with LPUI- 2Ts)
l 7720 W
(fully configured
with LPUF- 240s)
l 9040 W
(fully configured with LPUF- 480s)

l 12390 W
(fully configured with LPUI- 1Ts)

l 22450
W(fully configured with LPUI- 2Ts)
Typical heat dissipation l DC: 2595.5
BTU/hour (fully configured with LPUF- 51s)
l AC: 3082.2
BTU/hour (fully configured with LPUF- 51s)
l DC: 2984.9
BTU/hour (fully configured with LPUF- 120s)
l AC: 3471.5
BTU/hour (fully configured with LPUF- 120s)
10447
BTU/hour (fully configured with LPUF-240s)
20147.9
BTU/hour (fully configured with LPUF-240s)
3633.8
BTU/hour (fully configured with LPUF-200s)
l 13334.6
BTU/hour (fully configured with LPUF- 240s)
l 15475.9
BTU/hour (fully configured with LPUF- 480s)
l 21153.6
BTU/hour (fully configured with LPUI- 1Ts)
l 36013.1
BTU/hour (fully configured with LPUI- 2Ts)
l 25046.9
BTU/hour (fully configured with LPUF- 240s)
l 29329.6
BTU/hour (fully configured with LPUF- 480s)
l 40198.4
BTU/hour (fully configured with LPUI- 1Ts)
l 72837.2
BTU/hour (fully configured with LPUI- 2Ts)
DC input voltage l input voltage range :  -38.4 V to -72 V
l input rated voltage:  - 48 V/ -60 V
l input voltage range:   -38.4 V to -72 V
l input rated voltage:   - 48 V/ -60 V
l input voltage range:   -38.4 V to -72 V
l input rated voltage:   - 48 V/ -60 V
l input voltage range:   - 40 V to -72 V
l input rated voltage:   - 48 V/ -60 V
l input voltage range:   - 40 V to -72 V
l input rated voltage:   - 48 V/ -60 V
l input voltage range:   - 40 V to -72 V
l input rated voltage: -48 V/-60 V
AC input voltage l input voltage range: 180 V to 264 V
l input rated voltage:200 V to 240 V
Redundant powers 1+1 2+2 4+4 1+1 l [1T bundle] DC: 5+1
l [1T bundle] HVDC&AC: 4+1
l [2T bundle] DC: 7+1
l [2T bundle] HVDC&AC: 5+1
l [1T bundle] DC: 9+1
l [1T bundle] HVDC&AC: 7+1
l [2T bundle] DC: 12+1
l [2T bundle] HVDC&AC: 9+1
Redundant fans Support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F) l 2 assemblies
l Support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F)
l 2 partitions
l 2 assemblies/ partition, each partition in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F)
Support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F) l [1T bundle] 3
assemblies
in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F)
l [2T bundle] 3
assemblies in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F)
l [1T bundle] 2 partitions;
3
assemblies/ partition; each partition in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F)
l [2T bundle] 2 partitions;
3
assemblies/ partition; each partition in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F)
Airflow            
Operating temperature l Long-term: 0°C to 45°C (32°F to 113°F)
l Short-term:-5°C to +55°C (23°F to131°F)
l Remark:Restriction on the temperatur e variation rate: 30°C/hour (86°F/h)
Storage temperature -40°C to +70°C (-40°F to +158°F)
Relative operating humidity l Long term: 5% to 85% RH, non-condensing
l Short term: 5% to 95% RH, non- condensing
Relative storage humidity 5% to 95% RH,non- condensing
Long-term operating altitude <= 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the NEU100 must decrease by 1°C [33.8°F] for every 220 m [721.78 ft.].)
Storage altitude Less than 5000m (16404 ft.)

3.Ordering Information----NE40E-X3 Basic Configurations 
BOM Number Order Name Description
2351596 CR52-BKPE- 4U-DC Integrated DC Chassis Components(NE40E- X3)-4U,Including Dual DC Power
2355250 CR5B0BKP037 0 NE40E-X3 Integrated AC Chassis Components, (Including Dual AC Power)
3055705 CR5D0MPUD2 70 Main Processing Unit D3(Including 4G Memory and 2G USB)
2358577 CR5P03BASD7 3 NE40E-X3 Basic Configuration (Include NE40E- X3 Chassis,2 MPUs, 2 DC Power,without Software Charge and Document)
2358578 CR5P03BASA7 3 NE40E-X3 Basic Configuration (Include NE40E- X3 Chassis,2 MPUs, 2 AC Power(2200W),without Software Charge and Document)

Product display

Universal Service Router Ne40e-X16A Cr5p16basa76 AC Power Supply Chassis Mpu Sfu Port Netengine40e Network RouterUniversal Service Router Ne40e-X16A Cr5p16basa76 AC Power Supply Chassis Mpu Sfu Port Netengine40e Network RouterUniversal Service Router Ne40e-X16A Cr5p16basa76 AC Power Supply Chassis Mpu Sfu Port Netengine40e Network Router

Related product

Universal Service Router Ne40e-X16A Cr5p16basa76 AC Power Supply Chassis Mpu Sfu Port Netengine40e Network RouterUniversal Service Router Ne40e-X16A Cr5p16basa76 AC Power Supply Chassis Mpu Sfu Port Netengine40e Network RouterUniversal Service Router Ne40e-X16A Cr5p16basa76 AC Power Supply Chassis Mpu Sfu Port Netengine40e Network Router

Company Profile

Universal Service Router Ne40e-X16A Cr5p16basa76 AC Power Supply Chassis Mpu Sfu Port Netengine40e Network Router
Universal Service Router Ne40e-X16A Cr5p16basa76 AC Power Supply Chassis Mpu Sfu Port Netengine40e Network RouterUniversal Service Router Ne40e-X16A Cr5p16basa76 AC Power Supply Chassis Mpu Sfu Port Netengine40e Network Router

Our Advantages

The product is 100% genuine and has sufficient stock in stock;
Price discounts and fast delivery;
After sales service guarantee; Support sample and customization services.

FAQ

Q: Are you a trading company or a manufacturer? Can I use our own logo and label?
A: We are a trading company that provides domestic and international trade services. We also provide OEM/OEM services.

Q: What are the guarantees for product quality?
A: We have professional engineers who test each piece of equipment before shipment to ensure that the shipped products are in good condition.

Q: How did you resolve a defective product when I received it?
A: We have professional personnel to help you solve the problem. If the product is defective, we usually offer you a return, refund, or replacement of the defective product.

Q: What is your payment method and delivery time?
A: We accept credit cards, wire transfers, PayPal, and other payment methods. We also support fast shipping within 72 hours.

Q: What is the MOQ and how long is the warranty period?
A: The minimum order quantity for normal products is 1, and the product warranty period is usually 1 year.


Universal Service Router Ne40e-X16A Cr5p16basa76 AC Power Supply Chassis Mpu Sfu Port Netengine40e Network Router

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier